Diagram 2.2.5.13(e) - Exit doors shall not impede the egress of occupants when such doors<br />

sw<strong>in</strong>g open<br />

EXIT<br />

STAIRCA<br />

SE<br />

EXIT<br />

STAIRCASE<br />

EXIT<br />

STAIRCASE<br />

M<strong>in</strong>imum half the<br />

required clear width<br />

of the corridor<br />

COMMON CORRIDOR<br />

Door shall not encroach <strong>in</strong>to the required<br />

width of the land<strong>in</strong>g dur<strong>in</strong>g its sw<strong>in</strong>g<br />

EXIT<br />

PASSAGRWAY<br />

M<strong>in</strong>imum width of corridor as required under<br />

Cl. 2.2.3.7, Cl. 2.2.4.6 and Cl. 2.2.5.4<br />

EXIT<br />

PASSAGRWAY<br />

M<strong>in</strong>imum 1/2 width of corridor as required<br />

under Cl. 2.2.3.7, Cl. 2.2.4.6 and Cl. 2.2.5.4<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 44