Table 2.3.2A SIZE LIMITATION OF STATION AND COMPARTMENT<br />

(1)<br />

Compartments<br />

Compartment below ground level. No<br />

compartment to comprise more than one storey (*).<br />

Compartments between average ground level and a<br />

height of 24 m. No compartment to comprise more<br />

than 3 storeys.<br />

Compartments above a height of 24 m from<br />

average ground level. No compartment to comprise<br />

more than one storey.<br />

(2)<br />

Maximum<br />

Floor Area<br />

(3)<br />

Maximum<br />

Cubical Extent<br />

2000 m 2 7500 m 3<br />

4000 m 2 15000 m 3<br />

2000 m 2 7500 m 3<br />

(*) Size limitation of compartment below ground level is not applicable to the public area. Public area<br />

below ground level shall comply with Cl. 2.3.2.4(e).<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 78