(iv) The m<strong>in</strong>imum width and capacity of exit<br />

passageway shall comply with the<br />

requirements as provided <strong>in</strong> Cl.2.2.3.7,<br />

Cl.2.2.4.6 and Cl.2.2.5.4, and<br />

(v) Changes <strong>in</strong> level along an exit passageway<br />

requir<strong>in</strong>g less than two risers shall be by a<br />

ramp comply<strong>in</strong>g with the provisions under<br />

Cl.2.2.5.10, and<br />

(vi) If the exit staircase which connects to the<br />

<strong>in</strong>ternal exit passageway is pressurised, the<br />

<strong>in</strong>ternal exit passageway shall not be naturally<br />

ventilated but shall be mechanically ventilated,<br />

and it shall be pressurised to comply with the<br />

requirements <strong>in</strong> Section 2.6.<br />

(c) External exit passageway<br />

(i) An external exit passageway may be used as a<br />

required exit <strong>in</strong> lieu of an <strong>in</strong>ternal exit<br />

passageway, provided that the external wall<br />

between the exit passageway and the rest of<br />

the floor space may have ventilation open<strong>in</strong>gs<br />

of non-combustible construction, fixed at or<br />

above a level 1.8m, measured from the<br />

f<strong>in</strong>ished floor level of the passageway to the<br />

sill level of the open<strong>in</strong>gs and such ventilation<br />

open<strong>in</strong>gs shall be located not less than 3m<br />

from any open<strong>in</strong>g of an exit staircase, and<br />

(ii) An external exit passageway may not be<br />

subjected to the limitations of a maximum of<br />

two exit doors open<strong>in</strong>g <strong>in</strong>to the exit<br />

passageway, and<br />

(iii) An external exit passageway may be roofed<br />

over provided the depth of the roofed over<br />

portion shall not exceed 3m to avoid smoke<br />

logg<strong>in</strong>g, and<br />

(iv) An external exit passageway may be enclosed<br />

on the open side by only a parapet wall or solid<br />

balustrade of not more than 1m <strong>in</strong> height, and<br />

(v) Exit doors open<strong>in</strong>g <strong>in</strong>to an external exit<br />

passageway shall have fire resistance <strong>for</strong> at<br />

least half an hour and fitted with automatic<br />

self-clos<strong>in</strong>g device.<br />

External exit<br />

passageway<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 33