ADM100 Lesson: Monitoring Architecture<br />

Each component collects its own monitoring data using the infrastructure<br />

and stores it locally in the main memory. This part of the main memory<br />

is called the monitoring segment. You can configure the size of the<br />

monitoring segment.<br />

An<strong>SAP</strong>systemisselectedasthecentralmonitoringsystem. Itshould<br />

have as high a release status as possible (at least <strong>SAP</strong> R/3 4.6C) and a high<br />

level of availability. In large system landscapes, we recommend that you<br />

include a separate system that is used only special tasks such as central<br />

monitoring, Central User Administration, transport domains controller,<br />

or the <strong>SAP</strong> Solution Manager. From a performance point of view, the<br />

workload of the central monitoring system increases only insignificantly,<br />

as the collection of monitoring data is usually decentralized.<br />

The central monitoring system collects the monitoring data for the<br />

components and displays it in various views. In this way, the administrator<br />

has a central view of the entire system landscape. If errors occur, the<br />

administrator can jump directly from the central monitoring system to the<br />

appropriate component to correct a problem in a detailed analysis.<br />

Details<br />

The monitoring segment (in shared memory) is provided with a large<br />

q uantity of data about the system by different types of data collectors<br />

(active/passive). You can use either transaction RZ20 or the <strong>SAP</strong> Solution<br />

Manager to read and display the data. <strong>SAP</strong> also provides interfaces that<br />

allow external tools (such as HP Open View) to access this data.<br />

Definition of active/passive: An active data collector automatically collects<br />

data without an external trigger, for example the dispatcher. A passive<br />

data collector collects data due to a trigger, for example through the report<br />

<strong>SAP</strong>MSSY8, which runs every five minutes.<br />

The CCMS Alert Monitoring Infrastructure consists of three parts: Data<br />

collection, data storage, and administration.<br />