This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

Design of steel bridges to BS 5400: Part 3 485<br />

(a) Two or three vertical stiffeners should be provided, at a spacing of approximately<br />

one times the girder depth, close to the bearings; thereafter their spacing<br />

should be increased to 1.5 times the girder depth.<br />

(b) In general horizontal stiffeners should be avoided. In long span continuous plate<br />

girders they may be necessary in locations close to the piers.<br />

(c) It is desirable to provide vertical stiffeners on one side and horizontal stiffeners<br />

on the other side, where possible.<br />

(d) Initial values for web thickness are suggested in Table 17.3, if it is intended to<br />

provide web stiffening. Consideration should also be given to the economy of<br />

providing thicker webs, without any intermediate stiffening.<br />

(e) Compact girders are more economical for most simply supported spans and for<br />

shorter continuous spans; economical plate girders for longer continuous spans<br />

will be non-compact.<br />

17.6 Design of steel bridges to BS 5400: Part 3<br />

17.6.1 Global analysis<br />

The Code requires that the global analysis of the structure should be carried out<br />

elastically to determine the load effects, i.e. bending moments, shear forces etc. The<br />

section properties to be used will generally be those of the gross section (see clauses<br />

7.1 and 7.2 of the Code 2 ).<br />

Plastic analysis of the structure, i.e. redistribution of moments due to plastic hinge<br />

formation, is not allowed under BS 5400: Part 3.<br />

Analysis should be carried out for individual and unfactored load cases. Summation<br />

of the load effects in different combinations and with different load factors can<br />

then be carried out in tabular form, as required by the design process.<br />

17.6.2 Design of beams at the ultimate limit state<br />

17.6.2.1 Basis of design<br />

Table 17.3 Initial values of web thickness<br />

Beam depth (mm) Web thickness (mm)<br />

Up to 1200 10<br />

1200–1800 12<br />

1800–2250 15<br />

2250–3000 20<br />

Consideration should also be given to the economy<br />

of providing thicker webs, without any intermediate<br />

stiffening.<br />

In the design of beam cross sections at the ultimate limit state the following need<br />

to be considered.