This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

The equivalent effective length Le given below is based on the information given<br />

in References 7, 8 and 9 and is only valid for c/Lb < 0.15 and dc/D < 0.2, where Lb<br />

is the length of the beam and dc is the depth of the notch. All the other symbols are<br />

defined above. Beams with notches outside these limits should be checked as tee<br />

sections or stiffened.<br />

cK K<br />

L L<br />

L<br />

K K<br />

2<br />

Ê 2 + 2 2 ˆ<br />

e = bÁ1+<br />

˜<br />

Ë<br />

b ¯<br />

0<br />

= (for values of K0<br />

refer to [1])<br />

lb<br />

uvLb<br />

lb<br />

=<br />

r<br />

y<br />

( )<br />

u, v and ry are for I-beam sections and are defined in BS 5950: Part 1.<br />

The web angle cleat can become cumbersome when used to connect unequal sized<br />

beams. In this case it is necessary to notch the bottom flange of the smaller beam<br />

to prevent fouling of the bolts. Alternatively the cleat of the larger beam could be<br />

extended and the bolts placed below the bottom of the smaller beam.<br />

The essential detailing requirements for double angle web cleat connections are<br />

given in Fig. 26.14 and Table 26.6 gives the recommended design procedure.<br />

26.2.5.2 Flexible end-plates<br />

1<br />

Simple connections 741<br />

This type of connection is shown in Fig. 26.15. Like the double angle cleat connection,<br />

the top flange of the supported beam is notched to allow it to fit to the web of<br />

the supporting beam.<br />

If both beams are of a similar depth both flanges are notched. In either case, if<br />

the length of the notches exceed the limits given in section 26.2.5.1, the unrestrained<br />

web and beam must be checked for lateral torsional bucking. In practice the endplate<br />

is often detailed to extend to the full depth of the notched beam and welded<br />

to the bottom flange.This makes the connection relatively stiffer than a partial depth<br />

end-plate but provided the end-plate is relatively thin and the bolt cross centres<br />

are large, the end-plate retains sufficient flexibility to be classified as a simple<br />

connection.<br />

If the supporting beam is free to twist there will be adequate rotational capacity<br />

even with a thick end-plate. In the cases where the supporting beam is not free to<br />

twist, for example in a double sided connection, the rotational capacity must be provided<br />

by the connection itself. In such cases thick, full depth end-plates may lead to<br />

overstressing of the bolts and welds. Both partial and full depth end-plates derive<br />

their flexibility from the use of relatively thin end-plates combined with large bolt