This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

when the flange is very stiff, with no plastic deformation so that its flexural deformation<br />

is small relative to the elongation of the bolts, will the prying forces be<br />

insignificant.<br />

In BS5950-1: 2000 the tension capacity of a connection using bolts (including 90°<br />

countersunk head bolts) may be checked using either a simple method (clause<br />

6.3.4.2), which includes an allowance for prying forces, or a more exact method<br />

(clause 6.3.4.3) which explicitly accounts for prying action. The simple method may<br />

only be used in a connection where the cross-centre spacing of the bolt lines does<br />

not exceed 55% of the flange width or end-plate width. When using the simple<br />

method, if a connected part is designed assuming double curvature bending, its<br />

moment capacity per unit width should be restricted to the elastic resistance, pytp 2 /6,<br />

where tp is the thickness of the connected part. In the simple method the prying force<br />

need not be calculated but the tensile force per bolt, Ft, transmitted by the connection<br />

should not exceed the nominal tension capacity Pnom of the bolt, obtained from<br />

Pnom = 0.8ptAt, where At is the tensile stress area as specified in the appropriate bolt<br />

standard. For bolts where the tensile stress area is not defined, At should be taken<br />

as the area at the bottom of the threads and pt is the tension strength of the bolt<br />

obtained from Table 34.<br />

The more exact method may be used for a connection in which both of the connected<br />

parts satisfy one or more of the following:<br />

(a) the connected part spans between two or more supporting parts;<br />

(b) the outstand of the connected part is designed assuming single curvature<br />

bending;<br />

(c) the outstand of the connected part is designed assuming double curvature<br />

bending and the resulting prying force Q is calculated and included in the total<br />

applied tension Ftot in the bolt;<br />

(d) the connected part spans between two or more supporting parts in one direction,<br />

but acts as an outstand in the other direction, and the resulting prying force<br />

Q is calculated and included in the total applied tension Ftot in the bolt.<br />

In cases (a) and (b) no prying force is necessary for equilibrium. In the more exact<br />

method the moment capacity per unit width of the connected part should be taken<br />

as the plastic resistance, pytp 2 /4, and the total applied tension Ftot in the bolt, including<br />

the calculated prying force, should not exceed the tension capacity Pt, taken as<br />

ptAt.<br />

25.4 Plates loaded in-plane<br />

25.4.1 Deductions for holes<br />

Plates loaded in-plane 717<br />

Where holes are staggered the effective net section through the line of the holes is<br />

taken as the area of the gross cross section less a deduction of the area of the holes<br />

in any (zig-zag) section less s 2 t/4g for each gauge space in the line of holes (Fig.