Worked examples 501<br />

Subject Chapter ref.<br />

PLATE GIRDERS<br />

WE 17.10 Shear buckling resistance of web<br />

Design code Made by TMR Sheet no.<br />

BS 5950: Part 1 Checked by BD<br />

Webs with intermediate transverse stiffeners may be designed<br />

according to 4.4.5.2 or 4.4.5.3. The simplified method of 4.4.5.2 is<br />

used herein. The assumed stiffener spacing is shown in Fig.WE 17.2.<br />

WE 17.11 Shear buckling resistance of end panel AB<br />

The Code allows three alternative methods for providing end<br />

anchorage. The most commonly employed method is to design end<br />

panels without accounting for tension field action. For end panel<br />

AB:<br />

d = 2000 mm t = 15 mm Fv = 2300 kN<br />

a<br />

d<br />

pyw = 275 N/mm 2<br />

Pv = 0.6pywd t = 0.6 ¥ 275 ¥ 2000 ¥ 15 ¥ 10 -3 = 4950 kN<br />

q w = 132 N/mm 2<br />

Vw = qwd t = 132 ¥ 2000 ¥ 15 ¥ 10 -3 = 3960 kN<br />

V<br />

P<br />

V<br />

w<br />

v<br />

cr<br />

1550 d 2000<br />

= = 0. 775 = = 133<br />

2000<br />

t 15<br />

3960<br />

= =<br />

4950<br />

08 .<br />

9Vw - 2Pv<br />

9 ¥ 3960 - 2 ¥ 4950<br />

=<br />

=<br />

= 3677 kN<br />

7<br />

7<br />

F v = 2300 < Vcr = 3677 kN OK<br />

F v = 2300 < Pv = 4950 kN OK<br />

End panel AB should also be checked as a beam spanning between<br />

the flanges of the girder capable of resisting a shear force Rtf due<br />

to the anchor forces in panel BC.<br />

17<br />

5<br />

4.4.5<br />

4.2.3<br />

Table 21<br />

4.4.5.2<br />

4.4.5.4<br />

H.4.4<br />

Fig. 17.4