This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

Moment connections 755<br />

Table 26.10 Design checks for column splices – ends not prepared for contact in bearing<br />

Check Description Design rule<br />

no.<br />

1a Essential detailing<br />

requirements – flange<br />

cover plate on the<br />

outside<br />

See Fig. 26.24<br />

1b Essential detailing<br />

requirements – flange<br />

cover plates on the<br />

inside<br />

See Fig. 26.24<br />

2 Axial capacity of the For compression For tension<br />

flange cover plates The axial compressive The effective axial<br />

capacity of the cover tensile capacity of the<br />

plate (pyAfp) must be<br />

greater than the<br />

cover plate (pyAfp) must<br />

be greater than the<br />

maximum applied maximum applied tensile<br />

compressive force (F1max) force (F2max)<br />

3 Shear capacity of bolt The shear capacity of the bolt group (reduction<br />

group connecting the<br />

flange cover plate to<br />

factor ¥ SPs of the bolt shear capacities) must be<br />

greater than the maximum applied compressive<br />

column flange force (F1max)<br />

4 Bearing capacity of The bearing capacity of the flange cover<br />

flange cover plate<br />

connected to column<br />

flange<br />

plates (SPbs) must be greater than the maximum<br />

applied compressive force (F1,max)<br />

5 Shear capacity of bolt The shear capacity of the connecting bolt group<br />

group connecting web<br />

cover plate to column<br />

(SPs) must be greater than half the axial<br />

compressive load (due to factored loads) in the web<br />

web<br />

FcAw of the smaller column ( F3<br />

=<br />

2A<br />

)<br />

6 Axial capacity of web<br />

cover plate<br />

The axial capacity of the web cover plate (py Awp)<br />

must be greater than half the axial load in the web<br />

of the smaller column (F3)<br />

7 Bearing capacity of web<br />

cover plate connected<br />

The bearing capacity of the web cover plate (SPbs)<br />

must be greater than half the axial compressive<br />

to column web load in the web of the smaller column (F3)<br />

8 Structural integrity of<br />

splice<br />

As Table 26.9<br />

Note: The design check numbers may not match the check numbers given in Ref 1.<br />

Flush end-plate connections<br />

Extended end-plate connections<br />

Welded connections<br />

Each of these connection types is shown in Fig. 26.1. Choice of connection type is<br />

usually based on simplicity, duplication and ease of fabrication, all for economic<br />

reasons. Site welded joints are used extensively in the USA and Japan for the con-