This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

Worked examples 771<br />

Subject Chapter ref.<br />

No. 1<br />

COLUMN SPLICE<br />

Check 3 – Tension capacity of the cover plate<br />

Design code Made by DBM Sheet no.<br />

BS 5950 Checked by BD<br />

The basic requirement is that the net tension capacity of the cover<br />

plate must be greater than or equal to the applied net tension.<br />

The tension capacity of the cover plate is given by the following<br />

expression:<br />

Ft = pyAfp<br />

where py is the tensile strength of the plate<br />

A fp is the effective area of the cover plate<br />

A fp = KeAnet £ Agross<br />

where Ke is the effective net area coefficient ( for S275 steel Ke = 1.2)<br />

A net = 305 ¥ 10 - 2 ¥ 22 mm 2<br />

= 3006 mm 2<br />

Agross = 305 ¥ 10 mm 2<br />

= 3050 mm 2<br />

Afp = 1.2 ¥ 3006<br />

= 3607.2 mm 2<br />

Net area of the flange plate is greater than the gross area of the<br />

section therefore take the net area equal to the gross area.<br />

A fp = 3050 mm 2<br />

3050<br />

Ft = 275 ¥ kN<br />

1000<br />

= 838. 8 kN<br />

838.8 kN > 33.33 kN<br />

The tension capacity of the flange cover plates is satisfactory.<br />

26<br />

3<br />

3.4.3