This material is copyright - all rights reserved. Reproduced under licence from The <strong>Steel</strong> Construction Institute on 12/2/2007<br />

To buy a hardcopy version of this document call 01344 872775 or go to http://shop.steelbiz.<strong>org</strong>/<br />

<strong>Steel</strong> <strong>Designers</strong>' <strong>Manual</strong> - 6th Edition (2003)<br />

492 Plate girders<br />

f = 1<br />

when £ 56<br />

f = ≥ 156<br />

115<br />

f =<br />

1 15 + 0 002( -56)<br />

56 < < 156<br />

1.15<br />

l<br />

1.35<br />

when l<br />

.<br />

. . l<br />

when l<br />

The value of tl/ty is taken as the lower of tu/ty computed as above and 1.0.<br />

The term mfw in the above equations is a non-dimensional representation of the<br />

plastic moment resistance of the flange (taking the smaller value of the top and<br />

bottom flanges, ignoring any concrete).<br />

m<br />

fw<br />

Mp<br />

=<br />

dwet<br />

s<br />

s b f<br />

=<br />

2d<br />

t s<br />

2<br />

w yw<br />

yf fe f 2<br />

Values of tl/ty versus l are plotted in Figures 11–17 of the Code corresponding to<br />

various values of mfw and f. These can be used directly by designers.<br />

The term bfe is the width of flange associated with the web and is limited to<br />

Ê<br />

bfe £ 10tfÁ<br />

Ë s<br />

2<br />

we w yw<br />

355 12<br />

yf<br />

ˆ<br />

˜<br />

¯<br />

Where two flanges are unequal, the value of mfw is taken conservatively as the value<br />

corresponding to the weaker flange. Moreover, only a section symmetric about the<br />

mid-plane is taken as effective; any portion of the flange plate outside this plane<br />

of symmetry is ignored so that complexities due to the torsion of the flange are<br />

eliminated.<br />

The above procedure has to be repeated for several values of q, and the highest<br />

value of tu/ty is to be used. From parametric studies it has been established that q<br />

is never less than (1/3)cot -1 f or more than (4/3)cot -1 f.<br />

When tension field action is used, consideration must be given to the anchorage<br />

of the tension field forces in the end panels, and special procedures must be adopted<br />

for designing the end stiffener.<br />

17.6.2.6 Combined bending and shear (clause 9.9.3 of the Code)<br />

The Code has simplified the procedure for girders without longitudinal stiffeners<br />

by allowing shear and bending resistance to be calculated independently and then<br />

combined by employing an interaction relationship on the basis given below.<br />

(a) The bending resistance of the whole section is determined with and without<br />

contribution from the web (Ml and MR respectively).