Editing events<br />

You may add, change or delete events in the Time Code Events display.<br />

The changes are effective when you quit the Time Code Event display or<br />

press the Learn Mode softkey twice. 14<br />

Follow the procedure below to edit a time code program:<br />

Keystrokes:<br />

1. Use the arrow keys to<br />

highlight the field of the<br />

item you want to edit.<br />

2. Enter the new contents of<br />

the field. If you wish to<br />

delete the item, press<br />

[Clear].<br />

3. Press [Enter], or use the<br />

arrow keys to select<br />

another field.<br />

Actions:<br />

Selects field to edit<br />

Range editing<br />

If you wish to apply a change to a range of events, you may select multiple<br />

events and edit them all in a single step. For example, if you wanted to set<br />

the rates for your first ten events to 50 percent, proceed as follows:<br />

Keystrokes:<br />

1. Press [S7] until [S1] reads<br />

Select Event.<br />

Actions:<br />

2. Press [S1], Select Event. Prompt reads:<br />

Select event number<br />

3. Press [1] [Thru] [1][0].<br />

4. Press [S4], Rate. a<br />

The first rate field is highlighted<br />

Prompt reads:<br />

Select A/B Rate<br />

5. Press [5][0]. Sets the rate to 50 percent<br />

6. Repeat steps 6 and 7 for<br />

the remaining rate fields.<br />

a. Alternatively, you can press other softkeys at this point to edit<br />

code time, cue, submaster or macro settings.<br />

14.<br />

Pressing the Learn Mode key twice is a shortcut way to reset the<br />

event list pointer. See Re-setting the event list pointer, page 301, for<br />

information.<br />

306 Chapter 24 Control interfaces