Setting the port to Dimmer Doubling<br />

If your console is controlling an <strong>ETC</strong> Sensor dimming system that can<br />

operate in Dimmer Doubling mode, each dimmer and the port to which<br />

the dimmer is connected must be individually set to support that feature.<br />

Moving light fixtures cannot be patched to a doubled port.<br />

WARNING: Set the port mode using the procedure below BEFORE you<br />

create your patch. Changing a port to or from Dimmer Doubler mode<br />

unpatches all conventional lights and moving light fixtures controlled by<br />

that port.<br />

Use the following procedure to set a port’s mode to double. Use the<br />

procedure given under Setting dimmers to Dimmer Doubling, page 53, to<br />

set the mode of individual dimmers to double.<br />

1. Press [Setup] to display the Setup Menu.<br />

2. Press [2], Output Configuration, and press [Enter].<br />

3. Press [S1], DMX512 Port, enter the port to configure (port 1, 2 or 3).<br />

You may also use [↓] to select a port.<br />

4. Press [Enter].<br />

5. Press [1] to set the port for Dimmer Double mode or [0] to set the port<br />

for Normal mode.<br />

6. Press [Enter] twice to confirm your choice.<br />

7. Display identifies mode as either Normal or Double.<br />

Setting DMX512 speed<br />

If your console is controlling a dimming system that requires a slower<br />

DMX512 signal, specify this in the Output Configuration screen<br />

The console is designed to run at the highest rate provided for in DMX512<br />

specifications. Some dimming systems (including some Colortran ENR<br />

dimmers) may require a signal slower than the full DMX512 specification.<br />

If this proves necessary, you may reset the console’s signal speed.<br />

Speed choices are Slow, Medium, Fast, and Max. When installed, the<br />

console defaults to Max. If you have problems with outputs flashing,<br />

fades not running smoothly, or unselected dimmers rising spontaneously,<br />

experiment with slower speeds until the symptoms disappear. If the<br />

symptoms persist, please call <strong>ETC</strong> Technical Services at 800-775-4382.<br />

To reset the DMX512 signal speed, follow these steps:<br />

1. Press [Setup] to display the Setup Menu.<br />

2. Select 2, Output Configuration, and press [Enter].<br />

3. Press [S4], DMX512 Speed.<br />

4. Press [0] for Max, [1] for Fast, [2] for Medium, or [3] for Slow. The<br />

speed you choose appears in the upper right corner of the display.<br />

5. Press [Enter] to confirm your choice. The display shows the speed<br />

setting.<br />