Installing Remote Focus Unit<br />

The Remote Focus Unit (RFU) allows you to set channel levels, check<br />

dimmers or run cues from remote locations.<br />

To install the RFU, follow these steps:<br />

1. Verify that RFU power switch is turned Off. (Unit is off when switch<br />

is in the position toward the bottom edge of the RFU.)<br />

2. Insert the RFU cable into the connector on the back of the console or<br />

Remote Interface labeled, RFU.<br />

3. Turn RFU power switch to On.<br />

RFU console connector<br />

XLR 6-pin female<br />

RFU pinout<br />

1 Data (+) (to RFU)<br />

2 Data (–)<br />

3 Data (+) (from RFU)<br />

4 Data (–)<br />

5 Common (AC ground)<br />

6 +12 Vdc (fused, 2 amp)<br />

<strong>Expression</strong> 3 User Manual, v.3.1 341