Secondary Messages<br />

Dimmer # has a load, but the recorded load is zero. Because the<br />

recorded load is zero, the Dimmer Monitoring system is unable to<br />

determine whether the dimmer has a load error.<br />

The load on dimmer # has changed. Because the dimmer output is<br />

not at a high enough level, the Dimmer Monitoring system is unable<br />

to determine the size of the load. To correct the problem use [Check<br />

Loads] to determine the size of the load change.<br />

The load on dimmer # has changed from #W to #W. A decreased load<br />

indicates lamp failure. An increased load indicates that a lamp has<br />

been added since the last [Record Load]. Correct the problem or, to<br />

prevent further error messages, use [Clear Load] or [Record Load].<br />

DC output has been detected on dimmer #. If this condition persists,<br />

it may harm the connected load. Please check the connected load.<br />

An SCR has failed On/Off in dimmer #. The dimmer should be<br />

replaced.<br />

Dimmer # output has failed on. The dimmer should be replaced.<br />

Dimmer # output has failed off. Either the circuit breaker has tripped<br />

or the dimmer needs to be replaced.<br />

Dimmer #'s load has failed. The most likely cause is a lamp failure.<br />

Either replace the lamp or, to prevent further error messages, use<br />

[Clear Load] or [Record Load].<br />

Data error on Rack # DMX port A/B. Please check DMX cabling and<br />

connections between the console and the rack.<br />

Rack # ambient temperature is high at # degrees F. The temperature<br />

does not yet exceed acceptable operational limits, but the rack<br />

should be checked. Please check the cooling/ventilation in the<br />

dimmer room.<br />

Rack # ambient temperature is low at # degrees F. Please check the<br />

heating/ventilation in the dimmer room.<br />

Rack # ambient temperature is outside the acceptable operating<br />

range at # degrees F. Please check the cooling/ventilation in the<br />

dimmer room immediately.<br />

A ground fault (GFI/RCD) error has occurred in dimmer #. Use<br />

Dimmer status to determine the rack number for the dimmer.<br />

The phasing in Rack # is not allowed. The rack has been shut down.<br />

Please check the input power service.<br />

358 Appendix C Error messages