179<br />

ObJeCtS SUbJeCt tO rUleS FOr COnStrUCtIOn anD StampInG<br />

All boilers <strong>and</strong> pressure vessels subject to exemptions to the <strong>Boiler</strong>s <strong>and</strong> Pressure Vessels Act <strong>and</strong> regulations:<br />

1. <strong>Boiler</strong>s less than 30 kW.<br />

2. Pressure vessels less than 6 inches diameter, 1-1/2 cubic feet or 15 psi.<br />

ObJeCtS SUbJeCt tO rUleS FOr FIelD InSpeCtIOn<br />

Same as OBJECTS SUBJECT TO RULES FOR CONSTRUCTION AND STAMPING.<br />

InSpeCtIOnS reQUIreD<br />

1. <strong>Boiler</strong>s <strong>and</strong> pressure vessels: one annual external inspection or periodic as required by chief boiler inspector.<br />

2. Internal inspection is at the discretion <strong>of</strong> chief boiler inspector.<br />

InSUranCe InSpeCtIOn reQUIrementS<br />

1. Inspections made by any duly incorporated insurance company may be accepted, subject to chief boiler inspector’s recommendation,<br />

in lieu <strong>of</strong> inspections made by department.<br />

2. A copy <strong>of</strong> all inspection reports must be filed with chief boiler inspector within 21 days.<br />

3. Chief boiler inspector must be notified <strong>of</strong> cancelation, suspension, or rejection <strong>of</strong> insurance.<br />

CertIFICate OF InSpeCtIOn<br />

Certificate <strong>of</strong> Inspection is valid for 12 months or as specified by the chief boiler inspector.<br />

terrItOrY FeeS<br />

1. $60.00 CAD per hour for special inspections. No charge for annual inspections.<br />

2. <strong>The</strong>re is an annual registration fee which varies between boilers, pressure vessels, <strong>and</strong> size.<br />

mISCellaneOUS<br />

1. ASME CSD-1 will be adopted as reference code adopted as <strong>of</strong> June 2005.<br />

2. Repairs require a certified welder <strong>and</strong>/or approved contractor.<br />

3. Operators <strong>of</strong> boilers above 750 kW for low-pressure boilers <strong>and</strong> 100 kW for high-pressure boilers are required to be<br />

certified. Depending on rating <strong>and</strong> location <strong>of</strong> boiler, operator is required to be in attendance.<br />

4. <strong>National</strong> <strong>Board</strong> Inspection Code adopted as <strong>of</strong> June 2005.<br />

5. Installation permits are required for boilers <strong>and</strong> pressure vessels requiring registration <strong>and</strong> inspection in accordance<br />

with <strong>Boiler</strong>s <strong>and</strong> Pressure Vessels Act <strong>and</strong> regulations.<br />