216<br />

3. <strong>Boiler</strong>s operating at a pressure less than 15 psi when provided with an unassisted gravity return.<br />

4. <strong>Boiler</strong>s used exclusively for heating purposes when provided with an unassisted gravity return.<br />

5. Air tanks used solely for the operation <strong>of</strong> railroad signals <strong>and</strong> switches (when inspected annually by a competent inspector<br />

employed by the railroad company <strong>and</strong> when stamped with inspection date).<br />

6. <strong>Boiler</strong>s requiring annual inspection <strong>and</strong> certification by the State <strong>of</strong> Florida Bureau <strong>of</strong> Explosives <strong>and</strong> Fire Equipment,<br />

<strong>Boiler</strong> Safety Section.<br />

7. Portable boilers <strong>and</strong> unfired pressure vessels.<br />

InSpeCtIOnS reQUIreD<br />

1. High-pressure steam boilers: one semi-annual inspection.<br />

2. Unfired pressure vessels: one annual inspection.<br />

InSUranCe InSpeCtIOn reQUIrementS<br />

1. Reports <strong>of</strong> internal inspection must be filed with the department on <strong>National</strong> <strong>Board</strong> forms within 15 days.<br />

2. <strong>The</strong> department must be notified <strong>of</strong> suspension <strong>of</strong> insurance on account <strong>of</strong> dangerous conditions.<br />

3. <strong>The</strong> department must be notified <strong>of</strong> new business <strong>and</strong> discontinuance <strong>of</strong> insurance.<br />

CertIFICate OF InSpeCtIOn<br />

Certificate <strong>of</strong> Inspection for boilers <strong>and</strong> unfired pressure vessels, valid for 12 months, is issued by the department upon inspection<br />

<strong>and</strong> payment <strong>of</strong> the following certificate fees:<br />

1. Annual inspection fees:<br />

a. High-pressure steam boilers (fee includes semi-annual inspection) ...........................................................................$178.90<br />

b. Unfired pressure vessels ......................................................................................................................................................... $65.84<br />

c. Hot-water boilers...................................................................................................................................................................... $74.43<br />

d. Miniature boilers ........................................................................................................................................................................ $65.76<br />

mUnICIpal FeeS<br />

1. Installation permit fees (FY 2009 – 2010) include initial inspection <strong>and</strong> certificate (does not include installation or connection<br />

<strong>of</strong> fuel <strong>and</strong> water lines).<br />

2. Heating boilers (each):<br />

a. Less than 837,000 BTU per hour ........................................................................................................................................$107.34<br />

b. 837,000 BTU per hour to 6,695,000 BTU per hour .....................................................................................................$128.81<br />

c. Over 6,695,000 BTU per hour ...........................................................................................................................................$178.90<br />

d. Steam-driven prime movers .................................................................................................................................................. $85.88<br />

e. Steam-actuated machinery ..................................................................................................................................................... $85.88<br />

f. Unfired pressure vessels (operating at pressures in excess <strong>of</strong> 60 psi<br />

<strong>and</strong> having volume <strong>of</strong> more than 5 cubic feet) ................................................................................................................$107.34<br />

mISCellaneOUS<br />

1. Operator’s license is not required to operate a boiler.<br />

2. For boilers, water heaters <strong>and</strong> pressure vessels, see Florida Building Code 2004 (Mechanical), Chapter 10.<br />

3. Annual certification for boilers <strong>and</strong> unfired pressure vessels per Chapter 8, Miami-Dade County Code.<br />

2013 <strong>National</strong> <strong>Board</strong> Synopsis <strong>of</strong> <strong>Boiler</strong> <strong>and</strong> Pressure Vessel <strong>Laws</strong>, <strong>Rules</strong> <strong>and</strong> <strong>Regulations</strong>