256 UNITED STATES continued . . . Jurisdiction <strong>National</strong> <strong>Board</strong> ASME Texas NR, R, VR A, E, H, HLW, HV, M, N, NA, NPT, NV, PP, S, U, UD, U2, UV, V Utah NR, R, VR A, E, H, HLW, HV, M, N, NA, NPT, NV, PP, RP, S, U, U2, U3, UM, UV, V Vermont R, VR A, E, H, HLW, HV, M, PP, S, U, U2, UM, UV, V Virginia R All Washington NB, NR, R, VR All West Virginia NB, R, VR A, E, M, PP, S, V Wisconsin NR, R, VR All Wyoming None U, U2, U3, UV *Comes under the jurisdiction <strong>of</strong> the Illinois Department <strong>of</strong> Nuclear Safety. **High-pressure repairs <strong>and</strong>/or alterations to any boiler. CANADA Jurisdiction <strong>National</strong> <strong>Board</strong> ASME Alberta R* All when manufactured outside Canada British Columbia R* All Manitoba R*, VR H, S, U (if manufactured in U.S.) New Brunswick NR, R*, VR H, HLW, N, NV, PP, S, U Newfoundl<strong>and</strong> <strong>and</strong> Labrador R* All when manufactured outside Canada Northwest Territories R* A, E, H, HLW, HV, M, S, U, U2, UM, UV, V Nova Scotia R*, VR A, M, PP, S, U, U2, UM, UV, V Nunavut Territory R* A, E, H, HLW, HV, M, S, U, U2, UM, UV, V Ontario R* All Prince Edward Isl<strong>and</strong> NR, R*, VR H, HLW, HV, M, N, NA, NPT, NV, S, U, U2, UV, V Québec R* All when manufactured in the United States Saskatchewan R* All Yukon Territory *Accepted R* All 2013 <strong>National</strong> <strong>Board</strong> Synopsis <strong>of</strong> <strong>Boiler</strong> <strong>and</strong> Pressure Vessel <strong>Laws</strong>, <strong>Rules</strong> <strong>and</strong> <strong>Regulations</strong>
257 CITIES, COUNTIES, AND TERRITORIES OF THE UNITED STATES Jurisdiction <strong>National</strong> <strong>Board</strong> ASME Albuquerque, New Mexico R, VR A, E, H, HLW, HV, M, S, U, UM, UV, V Buffalo, New York R, VR H, S, U Chicago, Illinois All All Detroit, Michigan None All Los Angeles, California NR, R, VR A, H, HLW, HV, M, PP, S, U, UM, UV, V Miami, Florida None None Miami-Dade County, Florida None None Milwaukee, Wisconsin NR, R, VR All New Orleans, Louisiana NR, R, VR All New York, New York R, VR A, H, HLW, M, PP, S, UV, V Omaha, Nebraska R, VR A, E, H, HLW, HV, M, PP, S, U, U2, U3, V Puerto Rico NR, R, VR All Seattle, Washington All All Spokane, Washington R, VR A, E, H, HLW, M, PP, S, U, U2, UV, V St. Louis, Missouri R H, S, U, U2 Washington, D. C. VR A, E, H, PP, U 2013 <strong>National</strong> <strong>Board</strong> Synopsis <strong>of</strong> <strong>Boiler</strong> <strong>and</strong> Pressure Vessel <strong>Laws</strong>, <strong>Rules</strong> <strong>and</strong> <strong>Regulations</strong>
- Page 1 and 2:
® N B B I Since 1919 The National
- Page 3 and 4:
ii © 2013 The National Board of Bo
- Page 5 and 6:
iv Table oF ConTenTs UniTed sTaTes
- Page 7 and 8:
1 State Department G. Thomas Surtee
- Page 9 and 10:
3 State FeeS 1. Power boilers and h
- Page 11 and 12:
5 3. Air tanks located on vehicles
- Page 13 and 14:
7 State Department Randall D. Austi
- Page 15 and 16:
9 CertIFICate OF InSpeCtIOn Certifi
- Page 17 and 18:
11 3. Boilers and unfired pressure
- Page 19 and 20:
13 4. Certificate of Competency and
- Page 21 and 22:
15 Stamping: Where appropriate, the
- Page 23 and 24:
17 State Department Steve Nelson, C
- Page 25 and 26:
19 InSUranCe InSpeCtIOn reQUIrement
- Page 27 and 28:
21 d. Used solely for hot-water sup
- Page 29 and 30:
23 3. Any air tank on any vehicle u
- Page 31 and 32:
25 3. Examinations for Delaware ins
- Page 33 and 34:
27 These exempt hot-water supply bo
- Page 35 and 36:
29 6. Unfired pressure vessels havi
- Page 37 and 38:
31 State Department Keith A. Rudolp
- Page 39 and 40:
33 5. A pressure vessel — the con
- Page 41 and 42:
35 State Department Idaho Division
- Page 43 and 44:
37 2. Pressure vessels located on v
- Page 45 and 46:
39 c. Over 150 square feet ........
- Page 47 and 48:
41 4. Unfired pressure vessels meet
- Page 49 and 50:
43 a. Prepare a boiler or pressure
- Page 51 and 52:
45 State Department Michael Kloster
- Page 53 and 54:
47 III. Internal inspections of cas
- Page 55 and 56:
49 4. Hot-water supply boilers whic
- Page 57 and 58:
51 c. Boilers of 500 square feet he
- Page 59 and 60:
53 State Department Rodney J. Handy
- Page 61 and 62:
55 3. Low-pressure boilers: a. Heat
- Page 63 and 64:
57 3. Portable boilers used for agr
- Page 65 and 66:
59 8. A copy of the boiler rules an
- Page 67 and 68:
61 5. Steam-heating boilers, hot-wa
- Page 69 and 70:
63 4. Renewal of Maine Authorized I
- Page 71 and 72:
65 3. Air tanks installed on the ri
- Page 73 and 74:
67 State FeeS 1. Certificate inspec
- Page 75 and 76:
69 3. All air tanks, except when: a
- Page 77 and 78:
71 State Department William Vallanc
- Page 79 and 80:
73 2. Reports of internal inspectio
- Page 81 and 82:
75 State Department Joel T. Amato,
- Page 83 and 84:
77 ObJeCtS SUbJeCt tO rUleS FOr FIe
- Page 85 and 86:
79 State Department Kenneth L.Watso
- Page 87 and 88:
81 CertIFICate OF InSpeCtIOn Certif
- Page 89 and 90:
83 Stamping: Where appropriate, the
- Page 91 and 92:
85 State Department Keith Kelly, Co
- Page 93 and 94:
87 State Department Christopher B.
- Page 95 and 96:
89 4. Low-pressure boilers shall be
- Page 97 and 98:
91 State Department Mechanical Unit
- Page 99 and 100:
93 Mine Section jurisdiction: Same
- Page 101 and 102:
95 State Department George Capadis,
- Page 103 and 104:
97 CertIFICate OF InSpeCtIOn 1. Cer
- Page 105 and 106:
99 Stamping: 1. Repairs and alterat
- Page 107 and 108:
101 4. Shop Inspections, AIA Servic
- Page 109 and 110:
103 4. Containers for liquified pet
- Page 111 and 112:
105 State Department Matthew H. San
- Page 113 and 114:
107 CertIFICate OF InSpeCtIOn Certi
- Page 115 and 116:
109 1. Boilers and pressure vessels
- Page 117 and 118:
111 InSUranCe InSpeCtIOn reQUIremen
- Page 119 and 120:
113 State Department Robert Reetz,
- Page 121 and 122:
115 8. Insurance inspectors must ob
- Page 123 and 124:
117 3. Air tanks installed on the r
- Page 125 and 126:
119 State Department Department of
- Page 127 and 128:
121 State FeeS Annual Certificate o
- Page 129 and 130:
123 State Department Michael D. Gra
- Page 131 and 132:
125 InSUranCe InSpeCtIOn reQUIremen
- Page 133 and 134:
127 6. Air tanks installed on the r
- Page 135 and 136:
129 State Department Benjamin P. An
- Page 137 and 138:
131 2. Hot-water heating boilers wh
- Page 139 and 140:
133 State Department Adrienne Youma
- Page 141 and 142:
135 State Department Ira Hinkle, Ch
- Page 143 and 144:
137 mISCellaneOUS 1. Examinations f
- Page 145 and 146:
139 ObJeCtS SUbJeCt tO rUleS FOr CO
- Page 147 and 148:
141 State Department William H. Kun
- Page 149 and 150:
143 CertIFICate OF InSpeCtIOn Certi
- Page 151 and 152:
145 State Department Rick K. Sturm,
- Page 153 and 154:
147 4. Steel steam boilers: a. Annu
- Page 155 and 156:
149 4. Hot-water heaters and potabl
- Page 157 and 158:
151 3. Boilers of railroad companie
- Page 159 and 160:
153 3. An endorsement is required f
- Page 161 and 162:
155 8. API-510 (9th Edition). 9. Sp
- Page 163 and 164:
157 c. 500 square feet to 2,500 squ
- Page 165 and 166:
159 State Department David W. Mulli
- Page 167 and 168:
161 State Department Michael J. Ver
- Page 169 and 170:
163 6. Reporting of periodic inspec
- Page 171 and 172:
165 State Department J.D. Danni, OS
- Page 173 and 174:
167 2. ASME Code: all (for boilers
- Page 175 and 176:
169 1. National Board: R (accepted)
- Page 177 and 178:
171 prOVInCIal Department Terry W.
- Page 179 and 180:
173 prOVInCIal Department Eben L. C
- Page 181 and 182:
175 prOVInCIal Department neWFOUnDl
- Page 183 and 184:
177 mISCellaneOUS 1. Welders are su
- Page 185 and 186:
179 ObJeCtS SUbJeCt tO rUleS FOr CO
- Page 187 and 188:
181 2. Steam boilers on railway loc
- Page 189 and 190:
183 terrItOrY Department E. William
- Page 191 and 192:
185 prOVInCIal Department Anthony S
- Page 193 and 194:
187 InSpeCtIOnS reQUIreD Annual or
- Page 195 and 196:
189 e. All boilers, pressure vessel
- Page 197 and 198:
191 prOVInCIal Department Madiha M.
- Page 199 and 200:
193 b. Every time such an authorize
- Page 201 and 202:
195 ObJeCtS SUbJeCt tO rUleS FOr CO
- Page 203 and 204:
197 19. Periodic inspection or shop
- Page 205 and 206:
199 ObJeCtS SUbJeCt tO rUleS FOr CO
- Page 207 and 208:
201 InSUranCe InSpeCtIOn reQUIremen
- Page 209 and 210:
203 b. Pressure vessels meeting req
- Page 211 and 212: 205 mUnICIpal Department Michael J.
- Page 213 and 214: 207 mUnICIpal Department Gary J. Ba
- Page 215 and 216: 209 c. For each of the first five v
- Page 217 and 218: 211 Exceptions: 1. Equipment owned
- Page 219 and 220: 213 mUnICIpal Department Paul Herna
- Page 221 and 222: 215 mUnICIpal Department mIamI-DaDe
- Page 223 and 224: 217 mUnICIpal Department Randal S.
- Page 225 and 226: 219 mISCellaneOUS 1. Repairs/altera
- Page 227 and 228: 221 InSpeCtIOnS reQUIreD 1. Boilers
- Page 229 and 230: 223 5. Hot-water boilers located in
- Page 231 and 232: 225 mUnICIpal Department Thomas E.
- Page 233 and 234: 227 2. City of Omaha requires all b
- Page 235 and 236: 229 ObJeCtS SUbJeCt tO rUleS FOr FI
- Page 237 and 238: 231 c. Nominal water-containing cap
- Page 239 and 240: 233 mUnICIpal Department Alvin E. K
- Page 241 and 242: 235 CertIFICate OF InSpeCtIOn Certi
- Page 243 and 244: 237 mUnICIpal Department John McDon
- Page 245 and 246: 239 mUnICIpal Department Linda Argo
- Page 247 and 248: 241 mISCellaneOUS 1. Certificate of
- Page 249 and 250: 243 Iowa Michael Klosterman, Chief
- Page 251 and 252: 245 Washington Tony Oda, Chief Boil
- Page 253 and 254: 247 Puerto Rico Edgar Hernandez Com
- Page 255 and 256: 249 UNITED STATES continued . . . C
- Page 257 and 258: 251 ASME STANDARDS continued . . .
- Page 259 and 260: 253 UNITED STATES continued . . . J
- Page 261: 255 STAMpINg REqUIREMENTS BY JURISD