58<br />
c. Over 1,000 square feet heating surface .............................................................................................................................. $70.00<br />
4. Internal power boilers:<br />
a. 100 square feet or less heating surface ............................................................................................................................... $50.00<br />
b. Over 100 square feet to 1,000 square feet heating surface ........................................................................................... $75.00<br />
c. Over 1,000 square feet heating surface ............................................................................................................................$150.00<br />
5. Electric boilers:<br />
a. External ...................................................................................................................................................................................... $30.00<br />
b. Internal ....................................................................................................................................................................................... $50.00<br />
6. Coil-type steam generators ........................................................................................................................................................... $50.00<br />
7. Special inspection:<br />
a. $250.00 plus expenses for up to one-half day;<br />
b. $500.00 plus expenses for one day up to eight hours.<br />
8. ASME or <strong>National</strong> <strong>Board</strong> shop reviews for Certificate <strong>of</strong> Authorization are $1,500.00 per location.<br />
9. Quality control program reviews:<br />
a. <strong>Boiler</strong> <strong>and</strong> pressure vessel manufacturers <strong>and</strong> repair organizations:<br />
i. $250.00 plus expenses for up to one-half day;<br />
ii. $400.00 plus expenses for one day up to eight hours.<br />
b. Safety valve assembly <strong>and</strong> repair organizations:<br />
i. $250.00 plus expenses for up to one-half day;<br />
ii. $400.00 plus expenses for one day up to eight hours.<br />
10. Nuclear surveys:<br />
a. $250.00 plus expenses for up to one-half day;<br />
b. $500.00 plus expenses for one day up to eight hours.<br />
mISCellaneOUS<br />
1. <strong>The</strong> <strong>National</strong> <strong>Board</strong> Inspection Code is adopted for repairs <strong>and</strong> alterations.<br />
2. Certificate <strong>of</strong> Competency examinations are held by the boiler examining board on the first Wednesday in March, June,<br />
September, <strong>and</strong> December. An initial boiler inspector’s commission <strong>and</strong> identification card is issued (upon payment <strong>of</strong> a<br />
fee <strong>of</strong> $40.00) to those inspectors successfully passing the examination <strong>and</strong> obtaining a <strong>National</strong> <strong>Board</strong> Commission, or to<br />
inspectors holding a <strong>National</strong> <strong>Board</strong> Commission <strong>and</strong> who have passed an acceptable examination in another state. A fee<br />
<strong>of</strong> $20.00 is charged for the annual renewal <strong>of</strong> the identification card.<br />
3. Upon completion <strong>of</strong> the installation <strong>of</strong> a boiler or at the time <strong>of</strong> the initial certificate inspection <strong>of</strong> an already installed<br />
boiler that has not been inspected <strong>and</strong> decaled according to these rules, a decal with the state serial number shall be<br />
placed in a conspicuous location on the boiler/water heater for identification.<br />
4. All persons, firms, <strong>and</strong> corporations engaged in the installation, moving, <strong>and</strong> reinstallation <strong>of</strong> power boilers, steamheating,<br />
or hot-water heating boilers in the State <strong>of</strong> Louisiana, with the exception <strong>of</strong> the City <strong>of</strong> New Orleans, shall be<br />
licensed by the state fire marshal to perform such work. Before such license is issued, the applicant must pass a written<br />
examination administered by the chief boiler inspector.<br />
5. Before any boiler is installed, moved, or reinstalled, the licensed person, firm, or corporation must submit an application<br />
to the chief boiler inspector listing the location, manufacturer, type, serial number <strong>and</strong> <strong>National</strong> <strong>Board</strong> number <strong>of</strong> the<br />
boiler, <strong>and</strong> the expected date <strong>of</strong> installation completion.<br />
6. A license is required for a fee <strong>of</strong> $75.00, renewable annually, for the installation, moving, or reinstallation <strong>of</strong> power boilers,<br />
steam-heating boilers, <strong>and</strong> hot-water heating boilers. A written examination is required <strong>and</strong> is administered by the<br />
chief boiler inspector. Examination fee is $50.00. A permit is also required. Fee is $25.00 per unit for installation <strong>of</strong> each<br />
power boiler, steam-heating boiler, <strong>and</strong> hot-water heating boiler.<br />
7. A license is not required to operate a boiler or pressure vessel; however, an operator is required to be in attendance<br />
during operation.<br />
2013 <strong>National</strong> <strong>Board</strong> Synopsis <strong>of</strong> <strong>Boiler</strong> <strong>and</strong> Pressure Vessel <strong>Laws</strong>, <strong>Rules</strong> <strong>and</strong> <strong>Regulations</strong>