11.07.2015 Views

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 2<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> <strong>Cisco</strong> <strong>IOS</strong> Comm<strong>and</strong>scluster timercluster timerUse the cluster timer global configuration comm<strong>and</strong> on the switch stack or on the a cluster comm<strong>and</strong>switch to set the interval in seconds between heartbeat messages. Use the no form of this comm<strong>and</strong> toset the interval to the default value.cluster timer interval-in-secsno cluster timerSyntax Descriptioninterval-in-secs Interval in seconds between heartbeat messages. The range is 1 to 300seconds.DefaultsThe interval is 8 seconds.Comm<strong>and</strong> ModesGlobal configurationComm<strong>and</strong> HistoryRelease12.2(35)SE2ModificationThis comm<strong>and</strong> was introduced.Usage GuidelinesEnter this comm<strong>and</strong> with the cluster holdtime global configuration comm<strong>and</strong> only on the clustercomm<strong>and</strong> switch. The cluster comm<strong>and</strong> switch propagates the values to all its cluster members so thatthe setting is consistent among all switches in the cluster.The holdtime is typically set as a multiple of the heartbeat interval timer (cluster timer). For example,it takes (holdtime-in-secs divided by the interval-in-secs) number of heartbeat messages to be missed ina row to declare a switch down.ExamplesThis example shows how to change the heartbeat interval timer <strong>and</strong> the duration on the cluster comm<strong>and</strong>switch:<strong>Switch</strong>(config)# cluster timer 3<strong>Switch</strong>(config)# cluster holdtime 30You can verify your settings by entering the show cluster privileged EXEC comm<strong>and</strong>.Related Comm<strong>and</strong>sComm<strong>and</strong>show clusterDescriptionDisplays the cluster status <strong>and</strong> a summary of the cluster to which the switchbelongs.OL-9776-08<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> Comm<strong>and</strong> Reference2-123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!