11.07.2015 Views

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 2<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> <strong>Cisco</strong> <strong>IOS</strong> Comm<strong>and</strong>serrdisable recovery cause small-frameerrdisable recovery cause small-frameUse the errdisable recovery cause small-frame global configuration comm<strong>and</strong> on the switch stack oron a st<strong>and</strong>alone switch to enable the recovery timer for ports to be automatically re-enabled after theyare error disabled by the arrival of small frames. Use the no form of this comm<strong>and</strong> to return to the defaultsetting.errdisable recovery cause small-frameno errdisable recovery cause small-frameSyntax DescriptionThis comm<strong>and</strong> has no arguments or keywords.DefaultsThis feature is disabled.Comm<strong>and</strong> ModesGlobal configurationComm<strong>and</strong> HistoryRelease12.2(44)SEModificationThis comm<strong>and</strong> was introduced.Usage GuidelinesThis comm<strong>and</strong> enables the recovery timer for error-disabled ports. You configure the recovery time byusing the errdisable recovery interval interval interface configuration comm<strong>and</strong>.ExamplesThis example shows how to set the recovery timer:<strong>Switch</strong>(config)# errdisable recovery cause small-frameYou can verify your setting by entering the show interfaces user EXEC comm<strong>and</strong>.Related Comm<strong>and</strong>sComm<strong>and</strong>errdisable detect cause small-frameshow interfacessmall-frame violation rateDescriptionAllows any switch port to be put into the error-disabledstate if an incoming frame is smaller than the configuredminimum size <strong>and</strong> arrives at the specified rate (threshold).Displays the interface settings on the switch, includinginput <strong>and</strong> output flow control.Configures the size for an incoming (small) frame to causea port to be put into the error-disabled state.OL-9776-08<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> Comm<strong>and</strong> Reference2-193

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!