11.07.2015 Views

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 2<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> <strong>Cisco</strong> <strong>IOS</strong> Comm<strong>and</strong>serrdisable recoveryvmpsinterval intervalEnable the timer to recover from the VLAN Membership Policy Server(VMPS) error-disabled state.Specify the time to recover from the specified error-disabled state. The rangeis 30 to 86400 seconds. The same interval is applied to all causes. The defaultinterval is 300 seconds.NoteThe error-disabled recovery timer is initialized at a r<strong>and</strong>omdifferential from the configured interval value. The differencebetween the actual timeout value <strong>and</strong> the configured value can be upto 15 percent of the configured interval.DefaultsRecovery is disabled for all causes.The default recovery interval is 300 seconds.Comm<strong>and</strong> ModesGlobal configurationComm<strong>and</strong> HistoryRelease12.2(35)SE212.2(37)SEModificationThis comm<strong>and</strong> was introduced.The per-VLAN error-detection feature was added. The inline-power <strong>and</strong>sfp-mismatch keywords were added.Usage GuidelinesA cause (all, bpduguard, <strong>and</strong> so forth) is defined as the reason that the error-disabled state occurred.When a cause is detected on an interface, the interface is placed in the error-disabled state, an operationalstate similar to link-down state.When a port is error-disabled, it is effectively shut down, <strong>and</strong> no traffic is sent or received on the port. For theBPDU guard <strong>and</strong> port-security features, you can configure the switch to shut down just the offendingVLAN on the port when a violation occurs, instead of shutting down the entire port.If you do not enable the recovery for the cause, the interface stays in the error-disabled state until youenter the shutdown <strong>and</strong> the no shutdown interface configuration comm<strong>and</strong>s. If you enable the recoveryfor a cause, the interface is brought out of the error-disabled state <strong>and</strong> allowed to retry the operation againwhen all the causes have timed out.Otherwise, you must enter the shutdown <strong>and</strong> then the no shutdown comm<strong>and</strong>s to manually recover aninterface from the error-disabled state.ExamplesThis example shows how to enable the recovery timer for the BPDU guard error-disabled cause:<strong>Switch</strong>(config)# errdisable recovery cause bpduguardThis example shows how to set the timer to 500 seconds:<strong>Switch</strong>(config)# errdisable recovery interval 500You can verify your settings by entering the show errdisable recovery privileged EXEC comm<strong>and</strong>.OL-9776-08<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> Comm<strong>and</strong> Reference2-191

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!