11.07.2015 Views

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

Catalyst 3750-E and 3560-E Switch Cisco IOS ... - DNIP . NET

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

diagnostic startChapter 2<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> <strong>Cisco</strong> <strong>IOS</strong> Comm<strong>and</strong>sWhen specifying a test name, use the show diagnostic content privileged EXEC comm<strong>and</strong> to displaythe test ID list. To specify test 3 by using the test name, enter the diagnostic start switch number testTestPortAsicCam privileged EXEC comm<strong>and</strong>.If specifying more than one test to run, use the test-id-range parameter, <strong>and</strong> enter integers separated bya comma <strong>and</strong> a hyphen. For example, to specify tests 2, 3, <strong>and</strong> 4, enter the diagnostic start switchnumber test 2-4 comm<strong>and</strong>. To specify tests 1, 3, 4, 5, <strong>and</strong> 6, enter the diagnostic start switch numbertest 1,3-6 comm<strong>and</strong>.After starting the tests by using the diagnostic start comm<strong>and</strong>, you cannot stop the testing process.ExamplesThis example shows how to start diagnostic test 1 on stack member 2 when this comm<strong>and</strong> is entered on astack master:<strong>Switch</strong># diagnostic start switch 2 test 1<strong>Switch</strong>#06:27:50: %DIAG-6-TEST_RUNNING: <strong>Switch</strong> 2: Running TestPortAsicStackPortLoopback{ID=1} ...(switch-1)06:27:51: %DIAG-6-TEST_OK: <strong>Switch</strong> 2: TestPortAsicStackPortLoopback{ID=1} has completedsuccessfully (switch-2)This example shows how to start diagnostic test 2 on a stack member in a switch stack. Running this testdisrupts the normal system operation, causes the switch to lose stack connectivity, <strong>and</strong> then causes theswitch to reload.<strong>Switch</strong># diagnostic start switch 1 test 2<strong>Switch</strong> 1: Running test(s) 2 will cause the switch under test to reload after completion ofthe test list.<strong>Switch</strong> 1: Running test(s) 2 may disrupt normal system operationDo you want to continue? [no]: y<strong>Switch</strong>#16:43:29: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 <strong>Switch</strong> 2 has changed to state DOWN16:43:30: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 <strong>Switch</strong> 9 has changed to state DOWN16:43:30: %STACKMGR-4-SWITCH_REMOVED: <strong>Switch</strong> 1 has been REMOVED from the stack<strong>Switch</strong>#16:44:35: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 <strong>Switch</strong> 2 has changed to state UP16:44:37: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 <strong>Switch</strong> 2 has changed to state UP16:44:45: %STACKMGR-4-SWITCH_ADDED: <strong>Switch</strong> 1 has been ADDED to the stack16:45:00: %STACKMGR-5-SWITCH_READY: <strong>Switch</strong> 1 is READY16:45:00: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 <strong>Switch</strong> 1 has changed to state UP16:45:00: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 <strong>Switch</strong> 1 has changed to state UP00:00:20: %STACKMGR-4-SWITCH_ADDED: <strong>Switch</strong> 1 has been ADDED to the stack (<strong>Switch</strong>-1)00:00:20: %STACKMGR-4-SWITCH_ADDED: <strong>Switch</strong> 2 has been ADDED to the stack (<strong>Switch</strong>-1)00:00:25: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan (<strong>Switch</strong>-1)00:00:29: %SYS-5-CONFIG_I: Configured from memory by console (<strong>Switch</strong>-1)00:00:29: %STACKMGR-5-SWITCH_READY: <strong>Switch</strong> 2 is READY (<strong>Switch</strong>-1)00:00:29: %STACKMGR-5-MASTER_READY: Master <strong>Switch</strong> 2 is READY (<strong>Switch</strong>-1)00:00:30: %STACKMGR-5-SWITCH_READY: <strong>Switch</strong> 1 is READY (<strong>Switch</strong>-1)00:00:30: %DIAG-6-TEST_RUNNING: <strong>Switch</strong> 1: Running TestPortAsicLoopback{ID=2} ...(<strong>Switch</strong>-1)00:00:30: %DIAG-6-TEST_OK: <strong>Switch</strong> 1: TestPortAsicLoopback{ID=2} has completed successfully(<strong>Switch</strong>-1)This message appears if the configured test can cause the switch to lose stack connectivity:<strong>Switch</strong> 3: Running test(s) 2 will cause the switch under test to reload after completion ofthe test list.<strong>Switch</strong> 3: Running test(s) 2 may disrupt normal system operationDo you want to continue? [no]:2-144<strong>Catalyst</strong> <strong>3750</strong>-E <strong>and</strong> <strong>3560</strong>-E <strong>Switch</strong> Comm<strong>and</strong> ReferenceOL-9776-08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!