3. Configure email<br />

With this option (within the configuration menu) you setup how <strong>InterForm</strong>400 should send email<br />

if needed. It offers the possibility so use normal OS400 SMTP or <strong>InterForm</strong>400 SMTP:<br />

(The contents of the screen depends on the e-mail mode you select. Here all possible texts<br />

are displayed.)<br />

292 User’s <strong>Manual</strong> for <strong>InterForm</strong>400 ®<br />

Configure email SMP400D<br />

Email recovery subsystem : MAILINTER<br />

Library . . . . . . . : APF3812<br />

Email mode . . . . . . . . 2 1=IBM SMTP, 2=<strong>InterForm</strong> SMTP<br />

3=<strong>InterForm</strong> SMTP (register only)<br />

Automatic recovery<br />

Delay before retry . . . . 3 1-120 minutes<br />

Number of retries . . . 1 0-99<br />

Delay before retry . . . . 30 1-120 minutes<br />

Number of retries . . . 1 0-99<br />

Email gateway blank=no email gateway<br />

Host or ip address . . . .<br />

Port . . . . . . . . . . . 1-65535, blank=default port (25)<br />

BlueSeries integration<br />

Use when possible . . . . N Y=Yes, N=No<br />

Note:<br />

Subsystem MAILINTER must be active to enable automatic recovery.<br />

F3=Exit F10=Start MAILINTER subsystem F12=Cancel<br />

Subsystem MAILINTER not active - press F10 to start.<br />

The options are these:<br />

Email mode: 1=IBM SMTP: This is the default value and will make e-mailing from<br />

<strong>InterForm</strong>400 to run as in pre 2007 versions. This makes <strong>InterForm</strong>400 send<br />

out via OS400 SMTP and MSF servers. This requires that the SMTP and MSF<br />

servers are setup correctly and are running. Refer to Appendix N on page<br />

503 for more information of how to do that.<br />

2=<strong>InterForm</strong> SMTP: Use the <strong>InterForm</strong>400 SMTP instead of the IBM SMTP.<br />

It requires that the MAILINTER subsystem is running and that the <strong>System</strong> i is<br />

able to reach internet to e-mail itself or via the E-mail gateway.<br />

3=<strong>InterForm</strong> SMTP (register only): All e-mails sent from <strong>InterForm</strong>400 are<br />

not sent immediately but only registered. This can e.g. be used for testing.<br />

You can then at a later time (e.g. at night where the bandwidth is most<br />

probably not used) send all pending e-mails with the command<br />

APF3812/SNDMAILS. You can view the registered mails via the<br />

APF3812/WRKMAILLOG command.<br />

Automatic<br />

recovery: This is only relevant for <strong>InterForm</strong> SMTP. Here you setup the delay to use for<br />

the first retries (if the receiving mail server e.g. cannot be found) and the delay<br />

for additional retries.<br />

With the setup above <strong>InterForm</strong>400 will try to send the e-mail and then retry<br />

twice with a 3 minute delay. Then wait 30 minutes and then try once again. If<br />

still not found the e-mail will end up with status *FAILED in the mail log.<br />

Email<br />

Gateway: This is only used for <strong>InterForm</strong>400 SMTP. If you state a gateway this will be<br />

used as an external mail server for <strong>InterForm</strong>400. If you leave this field blank<br />

the <strong>System</strong> i must be able to reach the internet itself.