System Combinations 7-15<br />

Ultra3000 and Ultra5000 Drives with 115V Y-Series Motors, Continued<br />

2098-DSD-020, -020X, -020-DN, -020X-DN, -020-SE,<br />

2098-IPD-020, -020-DN, and Y-2006<br />

Torque 2.26<br />

20 Torque<br />

(N-m)<br />

(lb-in.)<br />

1.80<br />

16<br />

1.36<br />

0.90<br />

0.45<br />

0<br />

12<br />

8<br />

4<br />

0<br />

0 2000 4000<br />

Speed (RPM)<br />

=<br />

2098-DSD-020, -020X, -020-DN, -020X-DN, -020-SE<br />

2098-IPD-020, -020-DN<br />

Drive<br />

Motor Power Cable<br />

2090-UXNPAY-16Sxx<br />

Encoder Feedback<br />

2090-UXNFBY-Sxx<br />

Y-2006<br />

2098-DSD-020, -020X, -020-DN, -020X-DN, -020-SE,<br />

2098-IPD-020, -020-DN, and Y-2012<br />

Torque 4.52<br />

40 Torque<br />

(N-m)<br />

(lb-in.)<br />

3.39<br />

30<br />

2.26<br />

1.13<br />

0<br />

0<br />

20<br />

10<br />

0<br />

2000 4000<br />

Speed (RPM)<br />

System torque-speed characteristics<br />

Drive module input voltage = 115V AC RMS<br />

Ambient Temperature<br />

Motors: 0 to 40° C (32 to 104° F)<br />

Drives: 0 to 50° C (32 to 122° F)<br />

=<br />

2098-DSD-020, -020X, -020-DN, -020X-DN, -020-SE<br />

2098-IPD-020, -020-DN<br />

Drive<br />

Motor Power Cable<br />

2090-UXNPAY-16Sxx<br />

Encoder Feedback<br />

2090-UXNFBY-Sxx<br />

= Intermittent operating region<br />

= Continuous operating region<br />

Y-2012<br />

Length of cable xx is in meters: 01, 03, 09, 15, 30 (3.3, 9.8, 29.5, 49.2, 98.5 ft)<br />

Ultra3000 and Ultra5000 Drives with 230V Y-Series Motors<br />

2098-DSD-005, -005X, -005-DN, -005X-DN, -005-SE,<br />

2098-IPD-005, -005-DN, and Y-1002<br />

Torque 0.56<br />

5 Torque<br />

(N-m)<br />

(lb-in.)<br />

0.45<br />

4<br />

0.34<br />

0.23<br />

0.11<br />

0<br />

3<br />

2<br />

1<br />

0<br />

0 2000 4000<br />

Speed (RPM)<br />

2098-DSD-005, -005X, -005-DN, -005X-DN, -005-SE,<br />

2098-IPD-005, -005-DN, and Y-1003<br />

Torque 1.13<br />

10 Torque<br />

(N-m)<br />

(lb-in.)<br />

0.90<br />

8<br />

0.68<br />

0.45<br />

0.23<br />

0<br />

6<br />

4<br />

2<br />

0<br />

0 2000 4000<br />

Speed (RPM)<br />

System torque-speed characteristics<br />

Drive module input voltage = 230V AC RMS<br />

Ambient Temperature<br />

Motors: 0 to 40° C (32 to 104° F)<br />

Drives: 0 to 50° C (32 to 122° F)<br />

=<br />

=<br />

2098-DSD-005, -005X, -005-DN, -005X-DN, -005-SE<br />

2098-IPD-005, -005-DN<br />

Drive<br />

Motor Power Cable<br />

2090-UXNPAY-16Sxx<br />

Encoder Feedback<br />

2090-UXNFBY-Sxx Y-1002<br />

2098-DSD-005, -005X, -005-DN, -005X-DN, -005-SE<br />

2098-IPD-005, -005-DN<br />

Drive<br />

Motor Power Cable<br />

2090-UXNPAY-16Sxx<br />

Encoder Feedback<br />

2090-UXNFBY-Sxx Y-1003<br />

= Intermittent operating region<br />

= Continuous operating region<br />

= Drive operation with 115V AC RMS input voltage<br />

Length of cable xx is in meters: 01, 03, 09, 15, 30 (3.3, 9.8, 29.5, 49.2, 98.5 ft)<br />