04.02.2014 Views

GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8-46 <strong>Motion</strong> <strong>Control</strong> Accessories<br />

Right-Angle Connector Dimensions<br />

Figure 8.53<br />

Motor Power & Feedback Right-Angle Cable Dimensions<br />

Cable<br />

Max. Dia.<br />

Power<br />

Commutation<br />

BR<br />

Connector<br />

Max. Dia.<br />

CH<br />

1326AB/AS<br />

Servo Motor<br />

(460V)<br />

Cable Description CH 1<br />

mm (in.)<br />

1326-CPB1-RAx-xxx,<br />

1326-CPB1-RBx-xxx<br />

1326-CPB1T-RAx-xxx,<br />

1326-CPB1T-RBx-xxx<br />

1326-CPC1-RAx-xxx,<br />

1326-CPC1-RBx-xxx<br />

1326-CPC1T-RAx-xxx,1<br />

326-CPC1T-RBx-xxx<br />

1326-CCU-RAx-xxx,<br />

1326-CCU-RBx-xxx,<br />

1326-CECU-RAL-xxx,<br />

1326-CECU-RBL-xxx<br />

1326-CCUT-RAx-xxx,<br />

1326-CCUT-RBx-xxx,<br />

1326-CECUT-RAL-xxx,<br />

1326-CECUT-RBL-xxx<br />

1 CH is the cable connector height.<br />

Right-angle power cable for<br />

1326AB-B4xxxx, -B5xxxx, and<br />

1326AS-B3xxxx, -B4xxxx<br />

Flex-rated right-angle power cable for<br />

1326AB-B4xxxx, -B5xxxx, and<br />

1326AS-B3xxxx, -B4xxxx<br />

Right-angle power cable for<br />

1326AB-B7xxxx, and<br />

1326AS-B6xxxx, -B8xxxx<br />

Flex-rated right-angle power cable for<br />

1326AB-B7xxxx, and<br />

1326AS-B6xxxx, -B8xxxx<br />

Standard and high-resolution feedback<br />

cable, right-angle,<br />

for motor resolver<br />

Standard and high-resolution flex-rated<br />

feedback cable, right-angle, for motor<br />

resolver<br />

BR 2<br />

mm (in.)<br />

Connector<br />

Max. Dia.<br />

without -L option<br />

mm (in.)<br />

Connector<br />

Max. Dia.<br />

with -L option<br />

mm (in.)<br />

Cable<br />

Max. Dia.<br />

mm (in.)<br />

68.58 (2.7) 76.2 (3.0) 43.18 (1.7) 43.18 (1.7) 14.0 (0.55)<br />

68.58 (2.7) 104.1 (4.1) 43.18 (1.7) 43.18 (1.7) 10.4 (0.41)<br />

84.07 (3.31) 76.2 (3.0) 53.85 (2.12) 54.36 (2.14) 16.3 (0.64)<br />

84.07 (3.31) 160.2 (6.3) 53.85 (2.12) 54.36 (2.14) 16.0 (0.63)<br />

69.85 (2.75) 115 (4.5) 36.58 (1.44) 40.4 (1.59) 11.5 (0.45)<br />

69.85 (2.75) 120 (4.7) 36.58 (1.44) 40.4 (1.59) 11.5 (0.45)<br />

2 BR (bend radius) is the specified bend radius for standard 1326 cable assemblies. BR may vary on user-fabricated cables. For standard cable, BR is a one-time flex<br />

application. Flex cables have a much higher BR to withstand flex applications.<br />

Note: Lay all cables flat for 24 hours prior to installation. This allows the conductors to relax into their natural state and guards against internal twisting.<br />

Publication <strong>GMC</strong>-<strong>SG001E</strong>-<strong>EN</strong>-P — June 2001

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!