GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

GMC-SG001E-EN-P-JUN01 Motion Control Selection Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Reset<br />

Axis 0 Axis 1<br />

A B<br />

2<br />

1<br />

8<br />

7<br />

5<br />

6 2<br />

1<br />

A<br />

B<br />

4<br />

3<br />

A<br />

B<br />

8 4<br />

7 3<br />

6 2<br />

5 1<br />

A B<br />

SSI<br />

AEC<br />

Reset<br />

Axis 0 Axis 1<br />

A B<br />

2<br />

1<br />

8<br />

7<br />

5<br />

A<br />

B<br />

DANGER<br />

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY<br />

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.<br />

4<br />

3<br />

6 2<br />

1<br />

A<br />

B<br />

8 4<br />

7 3<br />

6 2<br />

5 1<br />

SSI<br />

A B<br />

AEC<br />

DANGER<br />

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY<br />

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.<br />

DANGER<br />

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY<br />

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.<br />

DANGER<br />

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY<br />

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.<br />

1394 Drive System Family 4-19<br />

Figure 4.13<br />

Two Standard <strong>GMC</strong> Systems’ Architectures (1394x-SJTxx-C and 1394C-SJT-xx-L)<br />

SLC 500<br />

ALEC<br />

RIO<br />

AxisLink<br />

845H<br />

Encoder<br />

PanelView<br />

AxisLink<br />

1394C-SJTxx-L<br />

DH-485<br />

1394x-SJTxx-C<br />

1326AB and 1326AS Motors<br />

Workstation with<br />

GML Commander<br />

1326AB and 1326AS Motors<br />

Resolver-based feedback only<br />

RS-232/-422<br />

845H Encoder<br />

Flex I/O<br />

Axis 1 Axis 0<br />

10<br />

9876<br />

2<br />

5<br />

43<br />

1<br />

10<br />

9876<br />

2<br />

5<br />

43<br />

1<br />

Configuration Encoder Power Encoder Configuration<br />

Switches Switches <strong>Control</strong><br />

SSI <strong>Control</strong><br />

842A<br />

Encoder<br />

Resolver-based feedback only<br />

Note:<br />

The Standard <strong>GMC</strong> system cannot support more<br />

than four total axis modules and auxiliary encoder<br />

input channels.<br />

Flex I/O<br />

4100-AEC<br />

Figure 4.14<br />

Two <strong>GMC</strong> Turbo Systems’ Architectures (1394x-SJTxx-T)<br />

PanelView<br />

SLC 500<br />

RIO<br />

AxisLink<br />

AxisLink<br />

ALEC<br />

845H<br />

Encoder<br />

SLC 5/03, 5/04, or 5/05 1<br />

DH-485<br />

1746-C7 or -C9 1<br />

1394x-SJTxx-T<br />

1394x-SJTxx-T<br />

1326AB and 1326AS Motors<br />

1326AB and 1326AS Motors<br />

Workstation with<br />

GML Commander<br />

RS-232/-422<br />

10<br />

9876<br />

2<br />

5<br />

43<br />

1<br />

Discrete Outputs<br />

Discrete Inputs<br />

Analog Outputs<br />

Analog Inputs<br />

Flex I/O<br />

Axis 1 Axis 0<br />

10<br />

9876<br />

2<br />

5<br />

43<br />

1<br />

Configuration Encoder Power Encoder Configuration<br />

Switches Switches <strong>Control</strong><br />

4100-AEC<br />

SSI <strong>Control</strong><br />

842A<br />

Encoder<br />

1<br />

Resolver-based Feedback Only<br />

Flex I/O<br />

This interface is only available with the 1394x-SJTxx-T system module.<br />

Resolver-Based Feedback Only<br />

Publication <strong>GMC</strong>-<strong>SG001E</strong>-<strong>EN</strong>-P — June 2001