Mechanical Assemblies 37<br />

VERTICAL COLUMN CHAIN REPLACEMENT<br />

WARNING... Verify that the Workstation keyswitch is in the OFF position.<br />

Observe safety procedures when operating motorized mechanical<br />

features.<br />

Electrical circuits inside the equipment use voltages that are capable<br />

of causing serious injury or death from electrical shock. Use<br />

appropriate precautions.<br />

Refer to Figure 16.<br />

1. Remove the Vertical Column motor and horizontal chains (perform the<br />

Vertical Column Motor Replacement procedure).<br />

2. To remove the left chain perform the following procedure:<br />

A. Remove the +24 VDC Power Supply.<br />

B. Disconnect wiring harness's P1 and P8 from the Power/Motor Relay PCB.<br />

C. Remove Torx screws (4 screws total) from all four corners of the Power<br />

Panel mounting assembly to expose the left Vertical Column chain.<br />

D. Loosen the chain tension screw until there is sufficient slack to loosen the 2<br />

hex bolts that secure the upper chain coupling to the vertical column.<br />

E. Remove the upper sprocket access plate by removing 2 horizontal<br />

support pins secured with snap rings and the 4 outside hex bolts that<br />

secure the plate to the casting.<br />

F. Remove the master links from both ends of the chain and remove the chain.<br />

3. To remove the right chain perform the following procedure:<br />

A. Loosen the chain tension screw until there is sufficient slack to remove<br />

the master links from both ends of the chain.<br />

B. Remove the upper sprocket access plate by removing 2 horizontal<br />

support pins secured with snap rings and the 4 outside hex bolts that<br />

secure the plate to the casting.<br />

C. Remove the master links from both ends of the chain and remove the chain.<br />

4. When installing either chain perform the following:<br />

A. Route the chain over the top and bottom sprockets and reattach the<br />

chain to the chain coupling with the master links.<br />

WARNING... Do not over tension either the vertical or horizontal chains.