42 Image System Calibration<br />

4. Adjust VR16, shown in Figure 37, to achieve a "flat" image with no bright spots<br />

located in the image. A slight overall brightness in the center of the image is<br />

acceptable.<br />

VR16<br />

REAR VIEW OF CAMERA PCB<br />

Figure 37 - VR16 Location<br />

5. Remove all test equipment from the system.<br />

6. THIS CONCLUDES THE BEAM & CCD CAMERA ALIGNMENT PROCESS.