13.07.2015 Views

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• IP address of the PC where the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software "server" is locat<strong>ed</strong>.• Port us<strong>ed</strong> for communication between the "Gateway Programmer" and the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software "server".• Enabling encryption of communication with the "Gateway Programmer".Setting the IP address of the serverThrough this function you can set IP address of the PC where the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software "server" is locat<strong>ed</strong>.IMPORTANT: The software automatically sets the correct configuration values ​when installing the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software.It's been implement<strong>ed</strong> to meet specific installation requirements and must be us<strong>ed</strong> only if agre<strong>ed</strong> with <strong>Vimar</strong>'s Client Service.DO NOT CHANGE THIS VALUE. THE INCORRECT SETTING OF THIS PARAMETER MAKES THE WELL-CONTACT SUITE SOFTWAREUNUSABLE.Setting the port us<strong>ed</strong> to communicate with the card programmerWith this function you can set the port address for communicating with the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software "card programmer".IMPORTANT: The software automatically sets the correct configuration values ​when installing the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software. It's beenimplement<strong>ed</strong> to meet specific installation requirements and must be us<strong>ed</strong> only if agre<strong>ed</strong> with <strong>Vimar</strong>'s Client Service. As also stat<strong>ed</strong> in theconfiguration window message, the information relat<strong>ed</strong> to the port MUST also be report<strong>ed</strong> on the "Gateway Configurator" configurationapplication.DO NOT CHANGE THIS VALUE. THE INCORRECT SETTING OF THIS PARAMETER MAKES THE WELL-CONTACT SUITE SOFTWAREUNUSABLE.To start the "Gateway Configurator" application, follow the path shown in the following picture.To set the port, <strong>ed</strong>it the "Port" field in the row corresponding to "Master Gateway".66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!