13.07.2015 Views

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The "Addresses/Objects Configuration" buttonThe following picture displays the "Addresses/Objects Configuration" button, locat<strong>ed</strong> on bottom right of the "ETS Configuration".Pressing "Addresses/Objects Configuration" opens the "Addresses/Objects Configuration", shown in the following figure.The "Addresses/Objects Configuration" window displays the list of all addresses/objects of the KNX automation system import<strong>ed</strong> into the <strong>Well</strong>-<strong>Contact</strong><strong>Suite</strong> software to set up some monitoring and diagnostic capabilities relat<strong>ed</strong> to the addresses/objects.For each defin<strong>ed</strong> address it is, in fact, possible to enable or disable the features list<strong>ed</strong> below:Addresses/Objects Configuration window'sentryService Start ReadingLog Requir<strong>ed</strong>Periodic ReadingReading RangeDescriptionWhen enabl<strong>ed</strong>, the software reads the status value of the relat<strong>ed</strong> address/object.If this feature is enabl<strong>ed</strong>, the software saves the select<strong>ed</strong> address/object status periodic reading to a databasetable.If this feature is enabl<strong>ed</strong>, the software performs a periodic reading of the select<strong>ed</strong> address/object status, usingthe value set in the "Reading interval" field as a reading interval (between a reading and the next).IMPORTANT: In order not to overload the KNX bus with an excessive amount of data you should use this functionwith caution, limiting it to when it's strictly necessary.Excessive bus traffic could in fact create delays on the execution of commands or even cause the malfunctionof the KNX automation system.The interval, in seconds, between a status reading and the next, where the by periodic reading of the select<strong>ed</strong>address/object status is enabl<strong>ed</strong>.IMPORTANT: In order not to overload the KNX bus with an excessive amount of data you should use this functionwith caution, avoiding to r<strong>ed</strong>uce the reading interval too much.Excessive bus traffic could in fact create delays on the execution of commands or even cause the malfunctionof the KNX automation system.IMPORTANT: For the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software to read the status of an address/object the possibility of reading the status must be enabl<strong>ed</strong> for theaddress/object. This operation must be verifi<strong>ed</strong> and possibly set using the KNX ETS3 software.You cannot change this setting from the <strong>Well</strong>-<strong>Contact</strong> <strong>Suite</strong> software.112

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!