• Creation• Display• Deleting a zone master• Deleting an item from a zone master• Editing Parameters• Assigning a master to set the default valuesCreating a zone masterThe proc<strong>ed</strong>ure for creating and configuring a zone master can be divid<strong>ed</strong> into two steps:• Creating the zone master. It is the phase during which the entity "master", or the virtual environment that will contain the various virtualdevices (functions master) is creat<strong>ed</strong>.The first phase will then create the "container", which is assign<strong>ed</strong> a descriptive name.• Inclusion of the functions masters that shall constitute the zone masterThe integration of different functions masters constituting the zone master can be done in three ways which are describ<strong>ed</strong> below and use the"drag & drop" method:a. The first method is to "drag" the functions masters previously creat<strong>ed</strong> in the ENVIRONMENT section to the icon of the zone master,(as describ<strong>ed</strong> in the chapter Configuring the "Functions master").This method will be describ<strong>ed</strong> later in paragraph "Method1: Association of existing functions masters with a zone master".b. The second method is similar, but does not require the master functions to be creat<strong>ed</strong> previously. In fact, it is possible to create thefunctions master directly from the ZONES section, using the "functions master" icon connect<strong>ed</strong> to the creat<strong>ed</strong> zone master. Thecreation of the functions master, although the proc<strong>ed</strong>ure starts in the ZONES section, is exactly the same as that describ<strong>ed</strong> in thechapter, the only difference being that the items to be associat<strong>ed</strong> with the functions master will be "dragg<strong>ed</strong>" to the icon of thefunctions master link<strong>ed</strong> to the zone master, in the ZONES section.This method will be describ<strong>ed</strong> later in paragraph "Creation of functions masters associat<strong>ed</strong> with a zone master".• The third method consists of creating the functions masters that make up the zone master automatically. Starting from thechoice of rooms to be controll<strong>ed</strong> by a zone master (which, as we have seen, can be consider<strong>ed</strong> as some kind of "virtual room").In this case we are directly going to "drag" the rooms to be controll<strong>ed</strong> through the zone master. The process automaticallycreates a functions master for each type of device includ<strong>ed</strong> in the rooms.If you don't want to use some of the functions master, you can delete them from the zone master (right-clicking them andselecting the "" menu selection that appears).This method will be describ<strong>ed</strong> later in paragraph "Creation of functions masters associat<strong>ed</strong> with a zone master".NOTE: If, when creating a zone master, a "double" thermostat is involv<strong>ed</strong> (art. code 14430 Plana, 16915 Idea; 20430 Eikon), which was ETS configur<strong>ed</strong>as a double thermostat, it is necessary to choose which thermostats must be associat<strong>ed</strong> to the master (only A, only B, both A+B)To make this choice, after entering the thermostat in the master, select the thermostat in the event master and choose the desir<strong>ed</strong> option from the"Details of the Device in the Select<strong>ed</strong> Functions Master" window.• Example1:Let's suppose a zone master ("north side rooms") has been creat<strong>ed</strong> for the control of two rooms (roomA and roomB)Let's suppose in roomA there are: a thermostat (thermostatA) and a l<strong>ed</strong>-type address to control a light (lightA).Let's suppose in roomB there are: a thermostat (thermostatB) of the "thermostat" type and a l<strong>ed</strong>-type address to control a light(lightB).If the two rooms are dragg<strong>ed</strong> to the "north side rooms" zone master, two functions masters will be automatically creat<strong>ed</strong> in themaster, each for a type of device or address includ<strong>ed</strong> in the rooms.- the master of the thermostats that will control the two thermostats: thermostatA and thermostatB;- the master of the lights that will control the two lights: lightA and lightB;Example2:Let's suppose a zone master ("south side rooms") has been creat<strong>ed</strong> for the control of two rooms (roomC and roomD)Let's suppose in roomC there are: a thermostat (thermostatC) and a l<strong>ed</strong>-type address to control a light (lightC).Let's suppose in roomD there are: two thermostats (thermostatD and thermostatE) of the "thermostat" type and two l<strong>ed</strong>-typeaddresses to control two lights (lightD and lightE).If the two rooms are dragg<strong>ed</strong> to the "south side rooms" zone master, two functions masters will be automatically creat<strong>ed</strong> in themaster, each for a type of device or address includ<strong>ed</strong> in the rooms.- the master of the thermostats that will control the three thermostats: thermostatC, thermostatD, and thermostatE;- the master of the lights that will control the three lights: lightC, lightD, and lightE.77

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!