13.07.2015 Views

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

Software Well-Contact Suite Office Linee guida ed ... - Vimar S.p.A.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

As anticipat<strong>ed</strong>, the result of each row in the list of the AND conditions is "put in AND" with the outcome of the next row, until there's no more rows in thelist.The overall result is obtain<strong>ed</strong> by performing logical AND operations between the results of all the logical expressions of the rows in the AND list, possiblyafter being deni<strong>ed</strong> (if you enabl<strong>ed</strong> the "Deny AND Conditions Output" field) and is put in AND with the overlying part, which is that of the OR conditions.The calculation of the final result of the expressions of the entire window, which activates the associat<strong>ed</strong> scenario, is done.Decision logic creationTo configure a decision logic, proce<strong>ed</strong> as follows:1. Press the "New" button from the list of decision logics.A new row appears in the alarm list, with the name "New n" (where n = integer).Make sure in the decision logic list the line corresponding to the new decision logic is select<strong>ed</strong>, and then proce<strong>ed</strong> with the following steps,which relate to the settings to be made using the fields in the "Select<strong>ed</strong> Logic/Alarm Retail".2. Changing the name of the decision logic. Select the "Name" field and type your text.We suggest you use brief but descriptive descriptions.3. Select the type "Decision Logic". By default when you create a new Logic/Alarm, "decision logic" is select<strong>ed</strong>.4. Define the logical conditions that generate the scenario execution event (refer to Chapter Definition of logical conditions for a detail<strong>ed</strong>description of the configuration window of the logical conditions).Press the button "Define Logical Conditions" to display the configuration window of the logical conditions.As an example, consider the following case. You want to use a logical decision to turn off the lights in the hallway of a hotel 10 minutes afterall the guests of the rooms of that hallway have enter<strong>ed</strong> the rooms (please note this example has only a didactic purpose).To do this you use the addresses relat<strong>ed</strong> to the enabling of power for individual rooms. Only when all these addresses take the value 1simultaneously, the scenario to turn off all the lights in the hallway can be execut<strong>ed</strong> (you can also insert a delay directly into the scenario, if youwant).Proce<strong>ed</strong> as follows:176

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!