HYDRAULIC FLUID RESERVOIR<br />

Removal and Installation<br />

Raise the operator cab. (See Page 1–1)<br />

Disconnect the hose (Item 1) [A] at the case drain filter<br />

and drain the fluid into a container.<br />

Loosen the hose clamp and disconnect the reservoir<br />

outlet hose (Item 1) [B].<br />

Disconnect the case drain hose (Item 2) [B] at the<br />

reservoir.<br />

Remove the bolt and plate from the mounting strap (Item<br />

1) [C] & [D].<br />

Installation: Tighten the bolt to 16–20 ft.–lbs. (21–27<br />

Nm) torque.<br />

Remove the mounting strap.<br />

Remove the hydraulic reservoir from the loa<strong>de</strong>r.<br />

A<br />

B<br />

C<br />

D<br />

1<br />

1<br />

1 2<br />

1<br />

CD–15130<br />

P–04856<br />

CD–15132<br />

P–4858<br />

853, 853H BICS Loa<strong>de</strong>r<br />

–2–65– Service Manual