HYDROSTATIC PUMP (Cont’d)<br />

853, 853H BICS Service Manual #6724012 – Hydrostatic System Section Part 2 of 3<br />

Assembly (Cont’d)<br />

Install a new gasket. Install the end cap over the centering<br />

screw. Turn the end cap up to the housing [A].<br />

Install the five bolts into the end cap [B].<br />

Tighten the bolts to 10–13 ft.–lbs. (14–18 Nm) torque.<br />

Center the piston using the measurement recor<strong>de</strong>d<br />

during disassembly [C].<br />

NOTE: The approximate distance between the<br />

piston and housing edge is 0.5 inch (12,7<br />

mm). Any measured adjustment is<br />

approximate. The final neutral adjustment<br />

must be performed with the pump installed<br />

and engine running.<br />

While holding the centering screw stationary, install the<br />

neutral adjustment lock nut [D].<br />

Revised June 96<br />