HYDRAULIC FILTER HOUSING<br />

Removal and Installation<br />

When making repairs on hydrostatic and<br />

hydraulic systems, clean the work area before<br />

disassembly and keep all parts clean. Always<br />

use caps and plugs on hoses, tubelines and<br />

ports to keep dirt out. Dirt can quickly damage<br />

the system.<br />

I–2003–0284<br />

Remove the hydrostatic filter housing. (See Page 2–66.)<br />

Disconnect the wire (Item 1) [A] from the sen<strong>de</strong>r.<br />

Disconnect the tubeline (Item 2) [A].<br />

Disconnect the hose (Item 1) [B].<br />

Remove the four mounting bolts (Item 2) [B].<br />

Installation: Tighten the mounting bolts to 25 ft.–lbs. (34<br />

Nm) torque.<br />

Remove the hydraulic filter/filter housing assembly.<br />

A<br />

B<br />

1<br />

2<br />

1<br />

2<br />

P–04872<br />

P–04861<br />

853, 853H BICS Loa<strong>de</strong>r<br />