DUAL PRESSURE MAIN RELIEF VALVE – 853H<br />

(Cont’d)<br />

Checking the High Setting<br />

The tools listed will be nee<strong>de</strong>d to do the following<br />

procedure:<br />

MEL10003 – Hydraulic Tester<br />

MEL10006 – Hydraulic Test Kit<br />

Turn the key switch to the OFF position. Before the<br />

engine stops running, turn the key switch all the way to the<br />

left to release the hydraulic pressure at the front auxiliary<br />

quick couplers.<br />

Lift and block the loa<strong>de</strong>r. (See Page 1–1.).<br />

Connect the hydraulic tester to the auxiliary quick coupler<br />

[A].<br />

The IN port on the tester connects to the female coupler<br />

on the loa<strong>de</strong>r.<br />

The OUT port from the tester connects to the male<br />

coupler on the loa<strong>de</strong>r.<br />

The hydraulic tester must be in the fully open<br />

position before you start the engine. I–2024–0284<br />

Put jackstands un<strong>de</strong>r the front axles and rear<br />

corners of the frame before running the engine<br />

for service. Failure to use jackstands can allow<br />

the machine to fall or move and cause injury or<br />

<strong>de</strong>ath.<br />

W–2017–0286<br />

Obtain a 3/8 inch (9,5 mm) I.D. hose (Item 1) [B] with a<br />

3000 PSI (20685 kPa) rating or greater.<br />

The hose loop (Item 1) [B] should be a total of 28 inches<br />

(711 mm) in length (including quick couplers).<br />

A small male coupler (Item 2) [B] (P/N 6648969) is<br />

nee<strong>de</strong>d for one end of the hose, and a small female<br />

coupler (Item 3) [B] (P/N 6648967) is nee<strong>de</strong>d for the other<br />

end of the hose.<br />

A 15K–5 fitting is also nee<strong>de</strong>d for each end of the hose<br />

[B].<br />

A 79K–6 O–ring is used toward the coupler si<strong>de</strong> of each<br />

fitting (this O–ring is inclu<strong>de</strong>d with each fitting).<br />

Install a 15K–5 fitting on each end of the hose loop.<br />

Install the female coupler (Item 3) [B] on one end of the<br />

hose loop.<br />

Drill orifice (P/N 6655091) size to .070 inch. Install the<br />

threa<strong>de</strong>d orifice (Item 1) [C] in the male coupler (Item 2)<br />

[C] and install the coupler on the fitting.<br />

A<br />

B<br />

C<br />

2<br />

1<br />

1<br />

2<br />

P–05195<br />

P–04717<br />

P–04757<br />

853, 853H BICS Loa<strong>de</strong>r<br />

–2–23– Service Manual<br />