ALTERNATOR (Cont’d)<br />

Rotor Continuity Test<br />

Touch the probes to the slip rings [A].<br />

The ohmmeter should read between 3.0–33.0 ohms.<br />

If there is no continuity replace the rotor.<br />

Rotor Ground Test<br />

Touch one probe to one of the slip rings and the other<br />

probe to the rotor shaft [B].<br />

There should be no continuity.<br />

Replace the rotor if there is continuity.<br />

Rectifier Continuity (Dio<strong>de</strong>) Test<br />

NOTE: In the dio<strong>de</strong> tests there should be continuity<br />

in one direction only. If the dio<strong>de</strong> being<br />

tested shows no continuity or continuity in<br />

both directions, replace the rectifier<br />

assembly.<br />

Touch the probes to the terminals of each dio<strong>de</strong> and read<br />

the meter [C].<br />

Reverse the probes to check the dio<strong>de</strong> in the other<br />

direction.<br />

There should be continuity in one direction only.<br />

Touch one probe to the dio<strong>de</strong> and the other probe to the<br />

connected heatsink and read the meter [D].<br />

Reverse the probes to check the dio<strong>de</strong> in the other<br />

direction.<br />

There should be continuity in one direction only.<br />

–6–10–<br />

A<br />

B<br />

C<br />

D<br />

P–01365<br />

P–01378<br />

P–01373<br />

P–01370<br />

853, 853H BICS Loa<strong>de</strong>r<br />