HYDROSTATIC PUMP (Cont’d)<br />

Disassembly (Cont’d)<br />

Mark the position of the neutral bracket for reference<br />

during assembly [A].<br />

NOTE: Removal of any part of the mechanical<br />

control will result in the loss of the neutral<br />

setting and will require neutral adjustment.<br />

Refer to Page 3–9 for the correct neutral<br />

adjustment procedure. The neutral<br />

adjustment procedure must be performed<br />

with the pump installed and engine running.<br />

Remove the flange head screw [B].<br />

Remove the control lever and spool assembly [C].<br />

If necessary, remove the spring from the control lever and<br />

spool assembly [D].<br />

Revised June 96<br />

A<br />

B<br />

C<br />

D<br />

CD–00065<br />

CD–00066<br />

CD–00067<br />

CD–00111<br />

853, 853H BICS Loa<strong>de</strong>r<br />

–3–39– Service Manual