AIR CLEANER HOUSING<br />

Removal and Installation<br />

Loosen the hose clamp (Item 1) [A].<br />

Disconnect the hose from the intake manifold.<br />

Loosen the hose clamp (Item 1) [B].<br />

Disconnect the intake hose from the air cleaner housing.<br />

NOTE: The manual indicator (Item 1) [C] is equipped<br />

on the 853 standard loa<strong>de</strong>r only.<br />

Remove the two mounting bolts (Item 2) [C] (at the top)<br />

and one mounting bolt at the bottom of the housing.<br />

Remove the air cleaner housing.<br />

NOTE: Disconnect the wires (Item 1) [D] from the<br />

sensor at the rear of the air cleaner housing.<br />

The sensor is equipped on 853 BOSS®<br />

option loa<strong>de</strong>rs only.<br />