HYDROSTATIC PUMP (Cont’d)<br />

Assembly (Cont’d)<br />

Apply petroleum jelly to a new O–ring. Install the O–ring<br />

on the plug [A].<br />

Apply oil to the high pressure relief valve cartridge. Install<br />

the high pressure relief valve cartridge, spring, shims (if<br />

equipped) and plug [A].<br />

Tighten the plug to 70–170 ft.–lbs. (95–230 Nm) torque.<br />

Charge Pump Assembly<br />

Apply oil to the gerotor assembly and gerotor cover.<br />

Install the gerotor assembly into the gerotor cover [B].<br />

Apply oil to the splined coupler (Item 1) [C] and drive pin<br />

(Item 2) [C].<br />

Install the splined coupler and drive pin into the gerotor<br />

assembly [C].<br />

The drive pin must be engaged in the gerotor slot.<br />

Install the gerotor assembly into the rear pump [D].<br />

NOTE: The gerotor assembly must be installed for<br />

the correct rotation.<br />

Pumps with split hydrostatic porting (two ports facing<br />

forward and two facing rearward) the pin (Item 1) [D] must<br />

be installed in the bottom holes (Item 2) [D].<br />

Make sure to install the gerotor assembly for the correct<br />

rotation. The pin (Item 1) [D] must be installed in the top<br />

hole (Item 3) [D] in the housing.<br />

Revised Mar. 03<br />

A<br />

B<br />

C<br />

D<br />

1<br />

1<br />

2<br />

3<br />

2<br />

CD–00057<br />

CD–00056<br />

CD–00055<br />

CD–00054<br />

853, 853H BICS Loa<strong>de</strong>r<br />

–3–57– Service Manual