LIFT LOCK BY–PASS VALVE<br />

Removal and Installation<br />

Never work on a machine with the lift arms up<br />

unless the lift arms are secured by a lift arm<br />

support <strong>de</strong>vice. Failure to use an approved lift<br />

arm support <strong>de</strong>vice can allow the lift arms or<br />

attachment to fall and cause injury or <strong>de</strong>ath.<br />

W–2059–0991<br />

When making repairs on hydrostatic and<br />

hydraulic systems, clean the work area before<br />

disassembly and keep all parts clean. Always<br />

use caps and plugs on hoses, tubelines and<br />

ports to keep dirt out. Dirt can quickly damage<br />

the system.<br />

I–2003–0284<br />

Raise the lift arms and install an approved lift arm support<br />

<strong>de</strong>vice. (See Page 1–1.)<br />

Raise the operator cab. (See Page 1–1.)<br />

Drain the fluid from the hydraulic reservoir. (See Page<br />

1–1.)<br />

Remove the control panel. (See Page 3–1.)<br />

Disconnect the tubelines (Items 1 & 2) [A].<br />

Disconnect the tubeline (Item 1) [B].<br />

Remove the two mounting bolts (Item 2) [B].<br />

Installation: Tighten the mounting bolts to 180–200<br />

in.–lbs. (21–23 Nm) torque.<br />

Turn the elbow fitting (Item 1) [C] for clearance.<br />

Disconnect the tubeline (Item 2) [C].<br />

Turn the lift lock by–pass valve so there is clearance to<br />

disconnect the tubeline (Item 1) [D].<br />

Remove the lift lock by–pass valve.<br />

A<br />

B<br />

C<br />

D<br />

1<br />

1<br />

1<br />

2<br />

2<br />

1<br />

2<br />

P–04747<br />

P–04748<br />

P–04749<br />

P–04750<br />

853,853H BICS Loa<strong>de</strong>r<br />

–8–17– Service Manual