174 Particle Generation Measuring MethodThe particle generation data for the SMC CLEAN SERIES are measured in the following test method.[Test method 1] (Example)Put the specimen in the acrylic resin chamber and operate it while supplying the same flow rate of clean air asthe suction flow rate of the measurement equipment (15 l/min). Measure the chronological changes of theparticle density until the number of cycles reaches the specified point.The chamber is located in a Class 100 clean bench.[Measurement conditions]Unobstructed 15lChamberQuality of supply air Same as the supply air for driving.ModelTS-1500Measuring Minimum measurableinstrument0.17µmparticle diameterInlet flow rate 15l/minManufacturerHitachi electronicengineering Co. Ltd.SettingconditionsNameSampling timeInterval timeSampling air flowLaser dust monitor(automatic particle counterby light scattering method)5min55min75l<strong>Clean</strong> system<strong>Clean</strong> gasfilter<strong>Clean</strong> gasfilter<strong>Clean</strong> bench (Class 100)Supply rate 15l/minExhaustedfrom relief portLaser dust monitor(Suction amount15l/min)Generated output measuring circuit[Evaluation method]To obtain the measured value of particle density, the accumulated value Note 1) of particles captured by the laser dustmonitor every 5 minutes is converted into the particle density in every 1m 3 .The value used to determine the particle generation grade Note 2) is considered to be 100% against the percentage of theaverage of actually measured particle density value assumed as 95%.The extra 5% is added to ensure cleanliness in the actual operation.The graphs are plotted based on the value considered to be 100% against the percentage of the average particelddensity as 95%. The extra 5% is added to ensure cleanliness in the actual operation.Note 1) Sampling air: Number of particles contained in 75l of airNote 2) Actuator: 1 million cyclesSolenoid valve: 20 million cycles Particle generationcharacteristics of CM2 Particle generationcharacteristics of CXSL Particle generationcharacteristics of CY1BParticle density (particles/m 3 )10 610 510 410 310 210Standardproduct10-CM211-CM2Particle density (particles/m 3 )10 610 510 410 310 210Standardproduct12-CXSL11-CXSLParticle density (particles/m3)10 610 510 410 310 210Standardproduct12-CY1B1 110.1 0.5 10.1 0.5 10.1 0.5 1Particle diameter (µm) Particle diameter (µm) Particle diameter (µm)Front matter 16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!