12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Solenoid Valve 10-SY3000/5000/7000290CautionBe sure to read before handling.Refer to pages 7 to 16 of Frontmatter for safety instructions andcommon precautions for cleanseries and pages 236 to 238 forcommon precautions fordirectional control valve.Specifications<strong>Series</strong>10-SY3000 10-SY5000 10-SY7000FluidAirInternal pilotoperating pressure rangeMPa2 position single2 position double3 position0.15 to 0.70.1 to 0.70.2 to 0.7Operating pressure range–100kPa to 0.7External pilotPilot 2 position single0.25 to 0.7operating pressure rangepressureMPa2 position double0.25 to 0.7range 3 position0.25 to 0.7Ambient and fluid temperature °CMax. 50Maximum operatingfrequency Hz2 position single, double3 position1035353Manual overridePilot exhaust methodNon-locking push type,Push-turn locking push type, Push-turn locking lever typeInternal pilotCommon exhaust (Pilot and main valve)External pilotIndividual pilot exhaustLubricationNot requiredMounting orientationFreeNote) Shock resistance/vibration resistance m/s 2Enclosure150/30Dust proof (∗DIN connector IP65)∗According to IEC529Note) Impact resistance: No malfunction resulted in an impact test using a drop impact tester.The test was performed in the axial and right angle directions of the main valve andarmature, for both energized and deenergized states. (Value in the initial stage).Vibration resistance: No malfunction resulted in a one-sweep between 8.3and 2000Hz. The test was performed on the axis and right angledirections of the main valve and armature, for both energized andde-energized states. (Value in the initial stage)Solenoid SpecificationsElectrical entryRated coil voltageDC50/60 Hz ACAllowable voltage fluctuationPower consumption W DCApparent power VA AC100V110V[115V]200V220V[230V]Surge voltage suppressorIndicator light∗The DIN terminal (D) is not available with 10-SY3000.∗110VAC and 115VAC are common, as are 220VAC and 230VAC.∗Energy saving type [0.22W] type is also available.Grommet (G)/(H), L plug connector (L),M plug connector (M), ∗DIN connector (D)24, 12, 6, 5, 3∗100, 110, 200, 220±10% of rated voltage0.5 {Lamp absorber: 0.55(DIN connector with lamp: 0.6)}0.9 (Lamp absorber: 1.0)1.0 (Lamp absorber: 1.1)[1.1 (Lamp absorber: 1.2)]1.8 (Lamp absorber: 1.9)1.9 (Lamp absorber: 2.0)[2.2 (Lamp absorber: 2.3)]Diode (ZNR for DIN terminal, zener diode for G, L or M non-polan type)LED (Neon bulb for AC type DIN terminal)DirectionalControl ValveResponse TimeNote) According to JISB8375-1981 dynamic performance test(With coil temperature of 20°C, at rated voltage and without surge voltage suppressor)10-SY3000Actuation2 position single2 position double3 positionResponse time ms(0.5 MPa)Withoutlight/surgeWith light/surge suppressersuppresser S, Z type R, U type12 or less 15 or less 12 or less10 or less 13 or less 10 or less15 or less 20 or less 16 or less10-SY7000Actuation2 position single2 position double3 positionResponse time ms(0.5 MPa)Without With light/surge suppresserlight/surgesuppresser S, Z type R, U type31 or less 38 or less 33 or less27 or less 30 or less 28 or less50 or less 56 or less 50 or less10-SY5000Actuation2 position single2 position double3 positionResponse time ms(0.5 MPa)Without With light/surge suppresserlight/surgesuppresser S, Z type R, U type19 or less 26 or less 19 or less18 or less 22 or less 18 or less32 or less 38 or less 32 or less271

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!