12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Series</strong> 10-ZSE5B/ISE5BDigital Pressure Switchwith Backlight651How to Order<strong>Clean</strong> seriesPiping specifications02 — Direct piping R1/4T2 — Direct piping NPTF 1/4Note) M5 X 0.8 threads are cut inside the piping.For Vacuum10 - ZSE5B - T2 - 27 L -MFor PositivePressure10 - ISE5B - 02 - 26 L-MOutput specifications26 —Analog output(1 to 5V)27 —NPN open collector (2 outputs)67 —PNP open collector (2 outputs)Lead wire lengthL — 3mUnit specificationsNil—With unit switching functionM —Fixed SI unit ∗∗) Fixed units For vacuum pressure or compound pressure: kPaFor positive pressure: MpaPart number of panel mounting adapter(Panel adapter A + Panel adapter B + Mounting bracket)ZS-22-EPanel adapter A·······ZS-22-03Panel adapter B·······ZS-22-02Mounting bracket·····ZS-22-04ZS-22-DM3 tapping screw 4 pcsOption bracketModelMin. displayFor positiveFor vacuumpressureModelZSE5B--26LZSE5B--27LZSE5B--67LISE5B--26LISE5B--27LISE5B--67LSpecificationsModelSet pressure range –100 to 100kPa –0.1 to 1MPaMax. operating pressure 200kPa1.5MPaLeak quantity1 X 10 -5 Pam 3 /skPa2 —MPa— 0.01mmHg10 —kgf/cm 20.02 0.1PSI0.2 10.02 0.1barIndicator lightResponse frequencyNote1)HysteresisOutput typeAnalog outputSwitch 2 outputAnalog outputSwitch 2 outputVacuum10-ZSE5BOutput specifications1 to 5V(5%F.S.)NPN open collector 30V, 80mAPNP open collector, 80mA1 to 5V(5%F.S.)NPN open collector 30V, 80mAPNP open collector, 80mAPositive pressure10-ISE5BLights up when ON(OUT1: Green OUT2: Red)200Hz (5ms)Hysteresis mode Variable (2digit or more) Variable (3digit or more)Windowcomparator mode Fix (2digit)Fix (3digit)Note1) Hysteresis modeIn case of ZSE The hysteresis is automatically set to 2 digits against the set value of P1 if thevalues of P1 and P2 are equal or P1>P2 applies with 2 digits or less hysteresis.In case of ISE: The hysteresis is automatically set to 3 digits against the set value of P1 if thevalues of P1 and P2 are equal or P1>P2 applies with 3 digits or less hysteresis.Window comparator modeIn case of ZSE: Set P1 and P2 5 digits or more apart because the hysteresis is 2 digits.In case of ISE: Set P1 and P2 7 digits or more apart because the hysteresis is 3 digits.∗1 digit refers to the minimum unit of pressure indication (See the above table).Panel adapter APanel adapter BFluidFluids that will not corrode SUS304, SUS630Temperature characteristics±3%F.S. or lessRepeatability±1%F.S. or lessOperating voltage12 to 24V DC (Ripple10% or less)Current consumption45mA or lessEmergency display Indicator light: Red lightening, Error display on LCDPressure indication 3 1/2 digit LED (Height of character 10 mm)Self diagnosis function (Over current (Note2) ), Excess pressure, Data error, Presence of pressure at the time of zero clearOperating temperature range 0 to 50°C (With no condensation)Noise resistance500Vp-p, Pulse width 1µS, Rise1nSWithstand voltage Between external terminal and case 250V AC 50/60Hz 1 minuteInsulation resistance Between external terminal and case 2MΩ(Measured with 50 V DC megameter)Vibration resistance1.5 mm amplitude in 10 to 500 Hz or acceleration of 98 m/s 2 ,whichever is smaller for 2 h in X, Y, Z direction eachShock resistance 980m/s 2 in X, Y, Z direction, 3 times eachWeight126g (Including 3m lead wire)Port size 02: R1/4, M5 X 0.8 T2: NPTF1/4, M5 X 0.8EnclosureIP40Note2) Not available with analog output types.Mounting bracket632

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!