12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Odor Removal Filter 10-AMF626Specific Product PrecautionsBe sure to read before handling.Refer to pages 7 to 16 of Front matter for safety instructions and common precautions with clean series. Refer topages 590 and 591 for common precautions for air preparation equipment.CautionDesignq Design a layout so that the mist separator is installed in anarea that is less susceptible to pulsation. The element couldbe damaged if the difference in internal and externalpressures exceeds 0.1 MPa.w Do not use the product with anything other than dry air (Suchas air containing moisture).e Be sure to install a micro mist separator (<strong>Series</strong> AMD), amicro mist separator with a prefilter (<strong>Series</strong> AMH) or a supermist separator (<strong>Series</strong> AME) on the primary side.r The bracket provided with the product is for supporting theproduct body. It cannot support the piping or otherconnection items. If these items need to be supported,provide an additional support.t Please see Front Matters P. 8 - 9 for the clean-up system ofair source used inside the clean room.CautionMountingq Confirm the compressed air flowdirection and the "" markindicating the inlet of the productbefore piping works. It cannot beused if connected in the oppositedirection.INOUTCautionMaintenanceq The replacement time of element cannot be providedexplicitly because it depends on the odor density ofcompressed air. Confirm the effective period of deodorizationand replace the element periodically thereafter.w When using the odor removal filter for the first time, confirmthe effective deodorization time. Thereafter, replace theelement on a regular basis.1) Record the date on which the odor removal filter is putinto operation.2) Calculate the total length of time that has elapsed fromthe time it was put into operation until it has started to emitoil odor.3) Use the time obtained in (2) as the guideline ofdeodorization performance retention period. If there is anychange in the operating conditions, please reconfirm thedeodorization performance retention period.e The element must be replaced when the pressure dropreaches 0.1 MPa or when two years have passed since theoperation start, whichever is earlier.r When it is time to replace the element, immediately replace itwith a new one. When replacing the element, also replacethe O-ring and the gasket with new parts.w Make sure to install this product on horizontal piping.Air PreparationEquipment607

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!