12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Solenoid Valve 10-VQ1000/2000408How to Order Valves10 - V Q 1 1 3 0 Y - 5 B - C6<strong>Clean</strong> seriesActuation2 position single(A)(B)4 212VQ10005 1 3(R1)(P)(R2)2 position double (Latching)(A)(B)4 2Metalseal5 1 3(R1)(P)(R2)(A)(B)4 25 1 3(R1)(P)(R2)RubbersealCylinder port sizeC3 — For ø3.2 One-touch fittingC4 — For ø4 One-touch fittingC6 — For ø6 One-touch fittingM5 — M5 threadManual overrideNil — Non-locking push type (tool required)B — Lock type (tool required)C — Locking type (lever)Note) The standard manual override for pilot valve is provided for double latching type.Coil voltage5 — 24VDC/With light/surge suppresser6 — 12VDC/With light/surge suppresserFunctionNil — Standard (1W): Double (latching) typeY — Low wattage (0.5W) specifications: Single typeSeal type0 — Metal seal1 — Rubber sealS Kit (Serial Transmission Kit)How to Order Manifold Assembly/Example3mSingle solenoid(24VDC)10-VQ1130Y-5-C6(4 sets)D side U side123--------------StationsDouble solenoid(24VDC)10-VQ1230Y-5B-C6 (4 sets)DirectionalControl ValveD-sub connectorcableF kitD-sub connector kitManifold base (8 stations)10-VV5Q13-08BFU2Cylinder portport sizeC6: For ø6One-touch fittingNote 2)SKitOABCDF1HWithout SI unitGeneral purpose type SI unitSI unit for Mitsubishi (MELSEC-A)SI unit for OMRON (SYSMAC)SI unit for Sharp (New Satellite)SI unit for NKE Corporation UNI-WIRE System (16 points)SI unit for NKE Corporation UNI-WIRE H System (16 points)Note 1)Maximum8 stationsNote 1) Using special wiring, semi-standard specifications with a larger maximum numberof stations are available.Note 2) Consult SMC regarding serial transmission kits by Matsushita Electric Industrial Co., Ltd.,Allen Bradley Co. , SUNX Limited, FUJI ELECTRIC CO.,LTD. and OMRON Corporation.10-VV5Q13-08BFU2 ······1 set (F kit 8 station manifold base part No.)∗ 10-VQ1130Y-5-C6 ······4 sets (Single solenoid part No.)∗ 10-VQ1230-5B-C6 ······4 sets (Double latching solenoid part No.)∗ To order valves and options mounted onto the manifold at the factory,prefix the part number of the solenoid valve and other equipment withan asterisk (∗).Specify the valves to be installed below the manifold part number. If thelayout is complicated, give descriptions on a manifold specification sheet.389

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!