12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5 Port Solenoid Valve Plug-in Type 10-SQ1000276Model<strong>Series</strong>Number ofsolenoidsModelFlow characteristics Note1)14/2 (PA/B) 4/25/3 (A/BR1/R2)C[dm 3 /(s·bar)] b Cv C[dm 3 /(s·bar)] b CvResponse time ms Note2)Standard: 1WLow wattageWeight(g)2 positionSingleDouble(Latching)Rubber seal 10-SQ1131Rubber seal 10-SQ12310.790.790.200.200.190.190.800.800.200.200.190.1915 or less20 or less20 or less—808010-SQ1000Closed center Rubber seal 10-SQ13310.640.200.150.580.260.1625 or less33 or less1003 positionExhaust centerRubber seal 10-SQ14310.640.200.150.800.200.1925 or less33 or less100Pressure center Rubber seal 10-SQ15310.790.210.190.590.200.1425 or less33 or less100Note 1) Cylinder port size of C6.Note 2) According to JISB8375-1981 (At supply pressure of 0.5MPa with light/surge voltage suppressor. The value differs with the pressure and the quality of air.)SpecificationsManifold SpecificationsValve specificationsSolenoidspecificationsValve typeFluidMaximum operating pressureMinimumoperatingpressureSingleAmbient and fluid temperatureLubricationPilot valve manual overrideNote2)Vibration Impact resistanceEnclosureRated coil voltageAllowable voltage fluctuationType of coil insulationPower consumption(Current)Double (latching)3 position24VDC12VDCRubber sealAir,Inert gas0.7MPa0.15MPa0.18MPa0.2MPaNote1) –10 to 50°CNot requiredPush type/Locking type (tool required)30/150 m/s 2Dust proof12V,24V DC±10% of rated voltageEquivalent to B class1W DC (42mA), Note3) 0.5W DC (21mA)1W DC (83mA), Note3) 0.5W DC (42mA)Note 1) Use dry air to prevent condensation when operating at a low temperature.Note 2) Vibration resistance: No malfunction resulted from a one-sweep test between 8.3 and 2000Hz.The test was performed on the axis and right angle directions of the main valve and armature, forboth energized and de-energized states.Impact resistance: No malfunction resulted in an impact test using a drop impact tester. The test was performedone time each in the axial and right angle directions of the main valve and armature, for bothenergized and deenergized states (specification).Note 3) Values for low wattage (0.5W)DirectionalControl ValveBase model10-SS5Q13--P, RC8(For ø8)Piping specificationsPort sizePipingSideNote 2)TopA, Bport sizeNote 1)C3 (For ø3.2)C4 (For ø4)C6 (For ø6)M5 (M5 thread)L3 (For ø3.2)L4 (For ø4)L6 (For ø6)L5 (M5 thread)ApplicablesolenoidvalveSQ131Connection typeF kit: D-sub connector26PP kit: Flat ribbon cable20PJ kit: PC wiring system compatibleflat ribbon cableS kit: Serial transmissionNote 1) The inch size one-touch fittings are also applicable.Note 2) Can be changed to side ported specification.Note 3) The maximum number of stations can be increased by adopting an optional special wiring specification.Note 4) Except valves.Note 3) Note 4) Note 4)Applicablestations1 to 12 stations1 to 12 stations1 to 9 stations1 to 8 stations1 to 8 stations5 stationsweight (g)420420420475Weight increaseper station (g)20202020257

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!