12.07.2015 Views

Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Solenoid Valve 10-VQ1000/2000399VQ1000/Base Mounted TypePlug Lead UnitHow to Order Manifolds<strong>Clean</strong> series<strong>Series</strong> VQ1000Plug lead unitValve stationsThe number of maximum stations differs from kit to kit.(Refer to the table below.)10 - V V 5 Q 1 2 - 08 C6 F U1 - D NCylinder port sizeC3 — For ø3.2 One-touch fittingC4 — For ø4 One-touch fittingC6 — For ø6 One-touch fittingM5 — M5 thread Note 1)CM — Mixture or with port plug Note 2)Note1) In case of M5, P and R ports are Rc1/8.Note2) In case of mixture or a type with port plug,give descriptions on a manifold specificationsheet.Kit designation/Electrical entry direction/Cable LengthRefer to the figure below.OptionNil — NoneB — Back pressure check valve Note 2)D — DIN rail mount type Note 3)K — Special wiring specification(Except double wiring) Note 4)N — With name plateNote 1) When more than one option is specified, list themin alphabetical order (e.g. -BDN).Note 2) If the option "-B" is specified, a back pressurecheck valve is installed on every station on themanifold. In case back pressure check valvesare required only on a certain number of stations,specify the mounting positions on a manifoldspecification sheet.Note 3) Since the DIN rail is standardized, be sure toinclude "-D".Note 4) Indicate the wiring specification on a manifoldspecification sheet (except C kit).Kit Designation/Electrical Entry Direction/Cable LengthF Kit (D-sub Connector Kit)P Kit (Flat Ribbon Cable Kit)Top entry Side entry Top entry Side entryNote 1)25PNote 1)26PConnector entryTop entry Side entryFKitNote 1) Besides the above, F kits with different number of pins are available.Note 2) Using special wiring, semi-standard specifications with a larger maximum number ofstations are available.380U0U1U2U3FKitS0S1S2S3Without cableWith 1.5 m cableWith 3 m cableWith 5 m cableConnector entryTop entry Side entryNote 2) U0S0 Without cableNote 2)Maximum8 stationsPKitU1U2U3PKitS1S2S3With 1.5 m cableWith 3 m cableWith 5 m cableMaximum8 stationsNote 1) Besides the above, P kits with different number of pins are available.Note 2) Using special wiring, semi-standard specifications with a larger maximum number ofstations are available.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!