Pneumatic Clean Series

Pneumatic Clean Series

Pneumatic Clean Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Solenoid Valve 10-VQ1000/2000402Model<strong>Series</strong>10-VQ1000SpecificationsNumber of solenoids2 position3 positionSingleDoubleClosed centerExhaust centerPressure centerMetal sealRubber sealMetal sealRubber sealMetal sealRubber sealMetal sealRubber sealMetal sealRubber sealFlow characteristics Note 1)WeightModel 14/2 (PA/B) 4/25/3 (A/BR1/R2)gResponse time Note 2)C[dm 3 /(s·bar)] b Cv C[dm 3 /(s·bar)] b Cvms10-VQ1110Y10-VQ1111Y10-VQ1210Y10-VQ1211Y10-VQ1310Y10-VQ1311Y10-VQ1410Y10-VQ1411Y10-VQ1510Y10-VQ1511Y0.700.850.700.850.680.700.680.700.700.850.150.200.150.200.150.200.150.200.150.200.160.210.160.210.160.160.160.160.160.210.721.00.721.00.720.650.721.00.720.650.250.300.250.300.250.420.250.300.250.420.180.250.180.250.180.180.180.250.180.18Note 1) Cylinder port size: C6 (without back pressure check valve).Note 2) According to JIS B8375-1981. (A value at supply pressure of 0.5MPa with light/surge voltage suppressor when clean air is used.The value differs with the pressure and the quality of air.) Values for double types are when the switch is ON.15 or less20 or less13 or less20 or less26 or less33 or less26 or less33 or less26 or less33 or less6478ValvespecificationsElectricalspecificationsValve typeFluidMax. operating pressureSingleMin. operating pressure Double3 positionAmbient and fluid temperatureLubricationManual overrideEnclosureRated coil voltageAllowable voltage fluctuationType of coil insulationPower consumption DC 24VDC(Current)12VDCNote 1) Use dry air to prevent condensation when operating at a low temperature.Metal sealRubber sealAir, Inert gas0.7MPa0.7MPa0.1MPa0.15MPa0.1MPa0.1MPa0.1MPa0.2MPa–10 to 50°C Note 1) –10 to 50°C Note 1)Not requiredPush type/Option: Locking type (tool required, lever)Dust proof12V, 24VDC±10% of rated voltageEquivalent to class B0.5W DC (21mA)0.5W DC (42mA)DirectionalControl ValvePrecautions to Install Threaded Fitting AssemblyThreaded fitting assemblys used for this manifold are not mounted on themanifold base or valve in order to improve installation efficiency ofconnecting the fittings to the port.Install the threaded fitting following the steps below.1.Screw in the fitting to the ancillary threaded fitting assembly.The fitting to be usedO ringThreaded fitting assemblyPrecautions1. Be careful not to scratch or stain the O-ring of the fitting assembly.It may cause air leakage.2. Do not screw in the fitting to the ancillary threaded fitting assemblyalready installed on the manifold base. If the screwing torque islarge, the manifold base may be damaged. To prevent exhaust air at EXH from pressurization (0.3 MPa or more)by throttling, double side piping is recommended for EXH port.(Otherwise delay in response or air leakage may result.)2.Insert the threaded fitting assembly into the manifold port.Manifold base3.Insert the ancillary clip into the groove on the bottom surfaceof valve.383

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!